C-LC-0202BTXN 133 70

C-LC-0202B; CIB, 2x RO switching contact, 230V / 16A (inrush 80A), 2x DI with local function

DI 2x DI
DO 2x RO (16A)
AI
AO
COM 1x CIB slave
SENSOR
Picture Variant Variant description
C-LC-0202B
C-LC-0202M is a module on the CIB bus. It is designed for mounting in an installation box. It contains:
- 2 relay outputs 16A (inrush 80) with a switching contact for switching power loads. especially light sources with a high short-term inrush current.
- 2 inputs are intended for connection of buttons with potential-free contacts and with evaluation of short and long presses. The inputs are also used for direct control of outputs if the module does not communicate with the CIB master.
Order num. TXN 133 70
Teco code TXN 133 70
Categories CFox - Built-in modules
Tags -
COM - System buses
CIB - Common Installation Bus (R): Installation I/O bus 1x CIB slave
DI - Organization of binary inputs
Total number of binary inputs 2
Number of groups of binary inputs 2
Organization of binary inputs into groups 1x (DI1) +1x (DI2)
DI - Parameters of binary inputs DC (group A)
Number of inputs in group 1
Input type active (for dry contacts connection)
Galvanic isolation of inputs from internal/peripheral circuits No
Diagnostics indication of energized input by LED on module panel
Max. measuring voltage on the connected contact 3,3 V DC
Internal input resistance 2 kΩ
Max. resistance for closed contact, log. 1 < 0,5 kΩ
Min. resistance for open contact, log. 0 > 1,5 kΩ
RO - Parameters of binary relay outputs (group A)
Number of relay outputs 2
Number of output groups 2
Number of outputs in group 1
Organization of relay outputs into groups 1x (DO1) + 1x (DO2)
Output type electromechanical relay, unprotected output
Contact type NO - Normally Open
Diagnose Alarm signaling on panel module
Switching current 16 A max., 100 mA min.
Switching voltage 300 V max., 5 V min.
Switching power 4000 VA max., 384 W max.
Short-term output overload - inrush 165 A max. (20 ms, max.), 800 A max. (20 μs max.)
Contact closing time typ. 10 ms
Contact opening time typ. 5ms
Mechanical life min. 5,000,000 cycles
Electrical life at rated load min. 25,000 switchings (20,000 for inrush 165 A)
Short-circuit protection No
Treatment of inductive load External RC element, varistor (AC), diode (DC)
Insulation voltage between outputs and internal circuits 4000 V AC
Isolation voltage between groups of outputs to each other work isolation
Power supply
Supply voltage, tolerances 24/27 V DC from CIB bus
Maximum power input 1,5 W
Power supply from CIB - maximum current consumption (mA) 50 mA
Power supply from CIB - Galvanic separation of power supply from internal circuits No
Size and weight
Weight approx. 75 g
Product dimensions (width x height x depth) 50 x 50 x 30 mm
Operating conditions, product standards
Product standard ČSN EN 60730-1 ed. 2:2001 (mod IEC 60730-1:1999)
Protection class of electrical object III, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) IP20
Operating areas Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution 1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007)
Overvoltage category installation II, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of device In the installation box, under the cover
Working position Any
Type of operation (operating frequency) Continuous
Ambient operating temperatures -10 °C to + 55 °C
Operating temperature minimum (° C) -10°C
Operating relative humidity from 10 % up to 95 % without condensation
Operating atmospheric pressure min. 70 kPa (<3,000 m above sea level)
Storage temperatures –25 °C to +70 °C
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / Emission ČSN EN 55022 ed2:2007 (mod CISPR22:2005)
Electromagnetic compatibility / Immunity min. according to ČSN EN 60730-1 ed.2: 2001
Sinusoidal vibration endurance 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.)
Installation
Assembly description The C-LC-0202B relay module can be mounted in any position in the installation box under the cover or under the device in the installation box. The installation is performed according to TXV 004 13.
Attention! The device may contain parts with dangerous voltages, covers being removed, or cabling manipulated, or disconnect the appropriate circuits or turn off the power !.
Connection
Connection description The C-LC-0202B module has a CIB bus and 2 inputs are connected to screw terminals, the switching contacts of the relay are connected using insulated wires with a length of approx. 80 mm terminated in sockets.
For more information, see the Peripheral Modules on the CIB TXV 004 13 manual. An example of the module connection is shown in the figure.
Connection of power and system communication terminal block with screw terminal 1.5 mm2
Specific I / O Relay outputs
Connection of specific I / O Insulated wires with sleeve
Module installation tools (-) 3 mm, flat screwdriver
Module operation
Commissioning The module is operated, set and diagnosed from the MOSAIC programming environment or other parameterization software. The module is ready for operation after connecting the supply voltage and the CIB bus. The HW address is indicated on the label on the module.
Module diagnostics The basic diagnostics is performed internally and the result is available in the relevant registers of the Mosaic environment. When the power is turned on, the RUN LED lights up green, after communication is established, it starts flashing. The switching status of the relay is indicated by a green LED.
Maintenance
Description The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected.
Notice Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!!
Warranty
Generally Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
Notice You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.

HW documentation

PDF

C-LC-0202B - Basic documentation

1.11 MB, (EN)

User manuals

PDF

Peripheral modules on the CIB Common Installation Bus(R) (en), TXV00413_02

13.94 MB, (EN, RU, DE, UA)

Files for designers

ZIP

Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.

20.49 MB
KNI

Foxtrot 2 - element library for SchemataCAD, v. 2024/01

6.79 MB

EC - Declaration of Conformity

PDF

Foxtrot - EC Declaration of conformity

295.20 kB, (EN, RU, DE, UA)
  • C-LC-0202B, a module for lighting control - The C-LC-0202B module is equipped with 2 relays with a switching contact; each is separately terminated by approx. 100mm long insulated wires. Continuous current in each output is 16 A, inrush current up to 800 A ( max. for 200 μ s) – s...
  • Switching light sources 230 VAC, module C-LC-0202B - To control 230VAC lights, we have a specialized module C-LC-0202B , designed to control two lights and place them in an installation box near the light sources. The module is equipped with two inputs, which are intended for connection of a push-...
  • 16 A relay (160 A switching current), the CFox and RFox peripheral modules - These relays are fitted in e.g. the C-OR-0011M-800 , C-LC-0202B , C-HM-1121M , R-HM-1121M peripheral modules, and others (see the information on the individual modules ).   Tab. 1. The parameters of the actual relay cont...
  • Switching power supply to the DSI, DALI, etc. ballasts - ...ng a relay contact with minimum switching current of 80 A for switching a single ballast, such as the C-OR-0008M or C-LC-0202B (it can be stated that a relay with inrush switching current below 40 A is of very little use for switching bal...
  • Switching of LED lighting, light bulbs, fluorescent lamps, etc. - ...r these loads - ie modules:   C-OR-0011M-800 11 relay outputs with short-term switching current up to 800 A C-LC-0202B 2 relay outputs with short-term switching current up to 80 A C-OR-0008M 8 relay outputs with short-term swit...

No data available.