Picture | Variant | Variant description |
---|---|---|
SC-1102 |
SC-1102; 1x CAN interface
The SC-1102 module is a system communication module enabling the expansion of the central unit by another serial channel supporting the CSJ mode.
A more detailed description of serial communications and their use is given in a separate manual Serial communication of TECOMAT programmable controllers - 32-bit model (order no. TXV 004 03.01).
Communication parameters are set in the Mosaic development environment within the project.
TECOMAT FOXTROT central units allow the connection of up to 6 system communication modules SC-1101 and SC-1102, which occupy channels CH5 - CH10. It should be borne in mind that due to the transmission capacity of the TCL2 bus, these serial channels are suitable for data- and time-consuming communications.
The SC-1102 module contains 1 CAN bus controller operated in CSJ mode.
The SC-1102 module is a system communication module enabling the expansion of the central unit by another serial channel supporting the CSJ mode.
A more detailed description of serial communications and their use is given in a separate manual Serial communication of TECOMAT programmable controllers - 32-bit model (order no. TXV 004 03.01).
Communication parameters are set in the Mosaic development environment within the project.
TECOMAT FOXTROT central units allow the connection of up to 6 system communication modules SC-1101 and SC-1102, which occupy channels CH5 - CH10. It should be borne in mind that due to the transmission capacity of the TCL2 bus, these serial channels are suitable for data- and time-consuming communications.
The SC-1102 module contains 1 CAN bus controller operated in CSJ mode.
Order num. | TXN 111 02 |
---|---|
Teco code | TXN 111 02 |
Categories | Foxtrot - Communication Modules (TCL2) |
Tags | - |
COM - Serial channels | |
---|---|
Number of internal CAN ports | 1 |
COM - System buses | |
TCL2 - system I/O bus | 1x TCL2 slave |
Power supply | |
Supply voltage, tolerances | 24 V DC, +25%, -15%, SELV |
Maximum power input | 0,8 W |
Module thermal/power loss | 0,8 W |
Galvanic separation of power supply from internal circuits | Yes |
Insulation voltage of galvanic separation | 1 000 VDC |
Internal protection | Yes |
Size and weight | |
Weight approx. | 75 g |
Product dimensions (width x height x depth) | 18 x 90 x 58 mm |
Module width in multiples of M (17.5 mm) | 1M |
Operating conditions, product standards | |
Product standard | ČSN EN 60730-1 ed. 2:2001 (mod IEC 60730-1:1999) |
Protection class of electrical object | I, according to ČSN EN 61140: 2003 (idt IEC 61140: 2001) |
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) | IP10B |
Operating areas | Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005) |
Degree of pollution | 1, according to ČSN EN 60664-1: 2004 (mod IEC 60664-1: 1992) |
Overvoltage category installation | II, acc. ČSN EN 60664-1:2004 (mod IEC 606641:1992) |
Type of device | Module on DIN rail |
Working position | Any |
Type of operation (operating frequency) | Continuous |
Ambient operating temperatures | 0 ° C to + 70 ° C |
Operating relative humidity | from 10 % up to 95 % without condensation |
Operating atmospheric pressure | min. 70 kPa (<3,000 m above sea level) |
Storage temperatures | –25 ° C to + 85 ° C |
Electromagnetic compatibility, Mechanical endurance | |
Electromagnetic compatibility / Emission | ČSN EN 55022 ed2:2007 (mod CISPR22:2005) |
Electromagnetic compatibility / Immunity | min. according to ČSN EN 60730-1 ed.2: 2001 |
Sinusoidal vibration endurance | 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.) |
Packaginng, transportation, storage | |
Description | The module is packed in a paper box. This documentation is also part of the package. The outer packaging is carried out according to the scope of the order and the method of transport in a transport package provided with labels and other data necessary for transport. The product must not be exposed to direct weather conditions during transport and storage. Malting of the product is only allowed in clean rooms without conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C |
Installation | |
Assembly description | Module is mounted in a vertical position on the U-rail ČSN EN 50022. Assembly installation (basic module and possibly peripheral modules) is performed according to TXV 004 10.01. |
Connection | |
Connection of power and system communication | terminal block with screw terminal 2.5 mm2 |
Module installation tools | (-) 2 mm, flat screwdriver |
Module connection | An example of module connection is shown in the following figure. The RS-485 line is terminated by switching both BT switches on the front panel of the module to the ON position (right). The CAN line must be terminated at a device located at each of the two ends of the line. If the device is connected in the middle of the line, termination is not performed. In this case, both BT switches will be to the left. |
Module operation | |
Commissioning | The module is operated as a system serial port, the settings are made in the Project Manager of the Mosaic programming environment, see the TXV 004 12 manual. |
Module diagnostics | The basic diagnostics is performed internally and the result is available in the relevant registers of the Mosaic environment. |
Maintenance | |
Description | The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected. |
Notice | Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!! |
Warranty | |
Generally | Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s. |
Notice | You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change. |
HW documentation
SC-1102 - Basic documentation
926.98 kB, (EN)
User manuals
Foxtrot 2 - Serial communication (en)
2.25 MB, (EN, RU, DE)
Files for designers
Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.
20.49 MB
Foxtrot 2 - element library for SchemataCAD, v. 2024/01
6.79 MB
EC - Declaration of Conformity
Foxtrot - EC Declaration of conformity
295.20 kB, (EN, RU, DE, UA)
- SC-1102, an additional interface CAN module - The SC-1102 module is a system communication module for expansion of the central unit by an additional port with CAN interface; the module contains one CAN bus control unit operating in the CSJ mode. A more detailed description of CAN s...
- Peripheral module address fixation on TCL2 - ...101 všechny verze 1.4 a vyšší SC-1102 všechny verze 1.6 a vyšší...
- Power dissipation of modules for calculation of switchboard heating - ...11 01 SC-1101 1x RS-232/RS-485 interface SC-1101 0,8 W TXN 111 02 SC-1102; 1x CAN interface SC-1102 0,8 W TXN 111 11.A SC-1111-A; RF interfac...
- Communication interface CH2 ÷ CH4, using multiple submodules - ...modules have three) are not enough, it is possible to add several serial channels RS-232, RS-485 or CAN via the SC-1101 and SC-1102 external communication modules. Table.1: Interface combination for individual channels in ac...
- SC-1101, an additional RS-232 and RS-485 interfaces - ...No. TXV 004 03.01). The Foxtrot basic module allows the connection of up to 6 system communication modules SC-1101 and SC-1102, which occupy the CH5 - CH10 channels. One should bear in mind that due to the transmission capacity of the TCL2 bus,...
No data available.