C-EM-0100MTXN 143 40

C-EM-0100M; CIB, 1 phase electricity meter 230 V AC

DI
DI/AI 1x DI/AI
DO
AI
AO
COM 1x CIB slave
SENSOR
Picture Variant Variant description
C-EM-0100M
Module of a 1-phase 4-quadrant electricity meter providing all parameters of consumed and supplied energy. The measurement is indirect, the current is sensed by a current transformer according to the required input range. The data is transmitted via a two-wire CIB - Common Installation Bus®
Order num. TXN 143 40
Teco code TXN 143 40
Categories CFox - Modules on DIN rail, Electricity meters
Tags -
COM - System buses
CIB - Common Installation Bus (R): Installation I/O bus 1x CIB slave
DI - Organization of binary inputs
Total number of binary inputs 1
Number of groups of binary inputs 1
DI - Parameters of binary inputs DC
Number of inputs in group 1
Common wire GND - module ground
Galvanic separation of inputs from CIB bus No
AI - Organization of analog inputs
Total number of analog inputs 1
Number of inputs per group 1
Input type AI / DI - combined
Common wire GND terminal
Galvanic separation from internal circuits No
AI - Analog Input Ranges
Passive sensor Pt1000, W100 = 1,385 (-90 to +320 °C)
Passive sensor Pt1000, W100 = 1,391 (-90 to +320 °C)
Passive sensor Ni1000, W100 = 1,500 (–60 to +200 °C)
Passive sensor Ni1000, W100 = 1.617 (-60 to +200 °C)
Passive sensor Resistance transmitter 0-160 kOhm
Passive sensor KTY81-121; (-55 to + 125 °C)
Passive sensor NTC Thermistor 12k / 25 °C (-40 to + 125 °C)
Measurement of supply network parameters - frequency
Nominal frequency 50/60 Hz
Frequency range 45 - 65 Hz
Measurement of supply network parameters - voltage
Rated voltage UNOM (UDIN) 180–250VAC
Crest factor in UNOM 2
Measuring range, phase voltage (UL-N) 20÷450 V AC
Voltage measurement accuracy ± 10% of value or ± 1% of range
Measurement category 300V CAT II
Input impedance 0,7 MΩ
Input consumption max. 0,09 VA
Permanent overload (UL-N) 1000 V AC
Peak overload, for 1 s (UL-N) 1300 V AC
Measurement of supply network parameters - currents
Method for measuring current indirect via current transformer
Nominal current of transformer Inom N * 0,05 A AC, max 65 A AC
Crest factor at Inom 1,8
Current measurement accuracy ±10% of value or ±1% of range
Input impedance 3 Ω
Input consumption max. 8 mVA
Permanent overload 0,25 A AC
Peak overload, for 5 s, repetition period min. 60 s 0,36 A AC
Measurement of supply network parameters - other quantities
Active power, measuring range (PNOM = UNOM × INOM×cosφ); [W, V, A] limited by measured voltage and current ranges
Reactive power, measuring range (QNOM = UNOM × INOM×sinφ); [VA, V, A] limited by measured voltage and current ranges
Accuracy of active or reactive power (A) ±10% of value or ±1% of range
Power supply
Supply voltage, tolerances 24/27 V DC from CIB bus
Power supply from CIB - typical current consumption (mA) 15 mA
Internal protection No
Size and weight
Weight approx. 53 g (65 g of double-sided proud transformative transformer)
Product dimensions (width x height x depth) 23 x 90 x 58 mm
Module width in multiples of M (17.5 mm) 1,5M
Operating conditions, product standards
Product standard ČSN EN 61131-2:2008 (idt IEC 61131-2:2007) - Programmable control units
Protection class of electrical object II, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) IP20
Operating areas Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution 2, according to ČSN EN 60664-1 ed.2: 2008 (idt IEC 60664-1: 2007)
Overvoltage category installation II, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of device Module on DIN rail
Working position Vertical
Type of operation (operating frequency) Continuous
Ambient operating temperatures -20 °C to + 55 °C
Operating relative humidity from 10 % up to 95 % without condensation
Operating atmospheric pressure min. 70 kPa (<3,000 m above sea level)
Storage temperatures –25 °C to +70 °C
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / Emission A, according to EN 55032 ed. 2: 2017 (idt CISPR 32: 2015)
Electromagnetic compatibility / Immunity min. according to ČSN EN 60730-1 ed.3: 2012
Sinusoidal vibration endurance 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.)
Packaginng, transportation, storage
Description The module is packed in a cardboard box. The product must not be exposed to direct weather conditions during transport and storage. The product must only be stored in clean rooms free from conductive dust, aggressive gases and vapours. The most suitable storage temperature is 20 °C.
Installation
Assembly description The module is mounted in a vertical position on the U-rail ČSN EN 50022. Installation of the assembly (basic module and possibly peripheral modules) is performed according to TXV 004 13.
Connection
Connection description The module is connected via screw terminals. The measured voltage is connected to terminal U via a suitable fuse with characteristics according to the environment (e.g. a fuse with a value of 0.05 A) and the neutral conductor to terminal N. To connect the current measurement, it is necessary to use a measuring current transformer with such a conversion ratio that the output current in the required measurement range is up to 0.05A AC and with the corresponding insulation voltage, or the transformer must be installed on an insulated primary conductor with the corresponding insulation voltage. The secondary winding of the transformer is connected to terminals S1 and S2. The CIB bus is connected to terminals CIB+ and CIB–.
Connection of power and system communication terminal block with screw terminal 0,2 - 2,5 mm²
Connection of inputs / outputs terminal block with screw terminal 0,2 - 2,5 mm2
Module operation
Commissioning The module is operated, set up and diagnosed from the MOSAIC programming environment or other parameterization software. The module is ready for operation after connecting the supply voltage and the CIB bus. The HW address is indicated on the label on the module.

Attention: When working with the module, it is necessary to observe all necessary measures to protect people and property from injury and damage by electric current!

The module must be operated by a person with the prescribed qualifications for such activity and this person must be thoroughly familiar with the principles of working with the module. If the module is connected to parts that are under dangerous voltage, it is necessary to observe all necessary measures to protect users and equipment from electric shock. The worker performing installation and/or maintenance of the device must be equipped with and use personal protective equipment and other safety equipment during work. If the module is used in a manner not specified by the manufacturer, the protection provided by the module may be reduced.

Further information can be found in the manual Peripheral modules on the CIB bus, order no.: TXV 004 13.01.
Module diagnostics Basic diagnostics are performed internally and the measurement results are available in the relevant registers of the Mosaic environment. The module status is indicated by the green RUN LED located on the front panel below the CIB bus connection terminals. After the CIB bus is connected, the green RUN LED lights up, indicating the presence of supply voltage on the CIB interface. After the module has established communication with the central unit, the RUN LED flashes. This means that the module is ready for operation.
Maintenance
Description The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected.
Notice Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!!
Warranty
Generally Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
Notice You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.

User manuals

PDF

Peripheral module on CIB-Common Installation Bus(R) (cs), TXV00413_01

14.01 MB
PDF

Peripheral modules on the CIB Common Installation Bus(R) (en), TXV00413_02

13.94 MB, (EN, RU, DE, UA)

HW documentation

PDF

Basic documentation C-EM-0100M

580.84 kB, (EN)

EC - Declaration of Conformity

PDF

Foxtrot 2 - EC Declaration of conformity (en)

590.59 kB, (EN, RU, DE, UA)

Files for designers

KNI

Foxtrot 2 - element library for SchemataCAD, v. 2025/08.

6.96 MB
ZIP

Foxtrot 2 - library of elements in DXF and DWG formats, v. 2025/08.

21.80 MB

No data available.

No data available.