C-RI-0401STXN 133 47

C-RI-0401S; CIB, 2x AI/DI RTD or contact; 1x IR transmitter, 1x IR receiver, 1x AI - light intensity (including IR LED+IR Sensor)

DI 2x AI/DI
DO
AI
AO
COM 1x CIB slave
SENSOR
Picture Variant Variant description
C-RI-0401S
C-RI-0401S is a module on the CIB Common Installation Bus®, which contains 2 analog / binary inputs, 1 input for the light sensor, 1 input for the IR receiver demodulator and 1 output for the IR transmitter.
Order num. TXN 133 47
Teco code TXN 133 47
Categories CFox - Built-in modules
Tags -
COM - System buses
CIB - Common Installation Bus (R): Installation I/O bus 1x CIB slave
DI - Parameters of binary inputs DC (group A)
Parameters valid for inputs on the terminals AI1/DI1, AI/DI2
Number of inputs in group 2
Common wire GND - module ground
Combined input type DI/AI Active, for sensing potential-free contacts and measuring resistance sensors
Galvanic isolation of inputs from internal/peripheral circuits No
Diagnostics signaling of excited input in Mosaic
Input voltage 3.3 V from internal source
Input current at log. 1 (typ.) 3,3 mA
Delay from log. 0 to log. 1 10 ms
Delay from log. 1 to log. 0 300 ms
The minimum width of the captured pulse 10 ms
AI - Organization of analog inputs
Total number of analog inputs 2
Common wire Plus
Galvanic separation from internal circuits No
External power supply No
Digital resolution 12 bit
Converter type Approximation
conversion time 500 μs
AI - Analog Input Ranges (Group A)
Parameters valid for inputs on the terminals AI1/DI1, AI/DI2
Passive sensor Pt1000, W100 = 1,385 (-90 to +400 ° C)
Passive sensor Pt1000, W100 = 1,391 (-90 to +400 ° C)
Passive sensor Ni1000, W100 = 1,500 (–60 to +200 ° C)
Passive sensor Ni1000, W100 = 1.617 (-60 to +200 ° C)
Passive sensor Resistance transmitter 0-160 kOhm
Passive sensor KTY81-121; PTC thermistor (-55 to + 125 °C)
Passive sensor NTC Thermistor 12k / 25 °C (-40 to + 125 °C)
Input impedance in signal range RTD > 1 kΩ
Resistance measurement error - maximum error at 25 ° C ± 2% of full scale
Resistance measurement error - temperature coefficient ± 0,1% of full scale
Resistance measurement error - non-linearity ± 0.2% of full scale
Resistance measurement error - repeatability at steady conditions 0.5% of full scale
Detection of disconnected sensor No
Input parameters for connecting a light sensor
Number of inputs 1
Galvanic isolation No
Lighting - Sensor type Photodiode BPW21
Lighting - Conversion time 500 μs
Lighting - Measuring range 0 lx ÷ 50000 lx
Lighting - Measurement error <5% of range
Lighting - Temperature coefficient ± 0.1% of full scale / ° C
Lighting - Linearity of measurements ± 0.2% of full scale
Lighting - Repeatability under steady state conditions 0.5% of full scale
Parameters of IR receiver / transmitter inputs / outputs
Number of inputs for connecting the IR receiver demodulator 1
Demodulator power supply 3,3 V
Galvanic separation from internal circuits No
Demodulator carrier frequency 36 kHz
Output parameters for IR transmitter connection
Number of outputs 1
Transmitter power supply 3,3 V
Short circuit protection No
Galvanic separation from internal circuits No
IR transmitter IR LED (IFMAX = 100mA) + resistor according to IF
IR transmitter, example IR LED UF = 1.2V, IF = 20mA → R = 100Ω
Power supply
Supply voltage, tolerances 24/27 V DC from CIB bus
Maximum power input < 0,5 W
Power supply from CIB - maximum current consumption (mA) 25 mA
Power supply from CIB - internal protection No
Size and weight
Weight approx. 7 g
Product dimensions (width x height x depth) 55 x 32 x 13 mm
Operating conditions, product standards
Product standard ČSN EN 60730-1 ed. 2:2001 (mod IEC 60730-1:1999)
Protection class of electrical object I, according to ČSN EN 61140: 2003 (idt IEC 61140: 2001)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) IP10B
Operating areas Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution 1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007)
Overvoltage category installation II, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of device In the installation box, under the cover
Working position Any
Type of operation (operating frequency) Continuous
Ambient operating temperatures -10 °C to + 55 °C
Operating relative humidity from 10 % up to 95 % without condensation
Operating atmospheric pressure min. 70 kPa (<3,000 m above sea level)
Storage temperatures –25 °C to +70 °C
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / Emission B, according to EN 55022: 1999 (mod CISPR22: 1997)
Electromagnetic compatibility / Immunity min. according to ČSN EN 60730-1 ed.2: 2001
Sinusoidal vibration endurance 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.)
Packaginng, transportation, storage
Description Модуль упакован в антистатический пакет. Эта документация также является частью пакета. Внешняя упаковка осуществляется в соответствии с объемом заказа и способом транспортировки в транспортной упаковке, снабженной этикетками и другими данными, необходимыми для транспортировки. Продукт не должен подвергаться воздействию прямых погодных условий во время транспортировки и хранения. Соложение продукта разрешено только в чистых помещениях. без токопроводящей пыли, агрессивных газов и паров. Наиболее подходящая температура хранения - 20 ° C.
Installation
Assembly description The C-RI-0401S module can be mounted in any position in the installation box or under the device cover. Installation of the assembly (basic module and possibly peripheral modules) is performed according to TXV 004 13.
Connection
Connection of power and system communication Ribbon flat conductors 0.15 / 0.5 mm2
Module connection The combined module is implemented as a CIB bus module, which provides communication. The power supply of the module is from an external source. The CIB bus can have any topology and branching up to a distance of 500 m and up to 32 units on one CIB branch. The CIB bus master is the FOXTROT basic unit or module, for example MI2-02M. Further information can be found in the manual Peripheral modules on the CIB TXV 004 13.
An example of module connection is shown in the following figure.
Module operation
Commissioning The module is operated, set and diagnosed from the MOSAIC programming environment or other parameterization software. The module is ready for operation after connecting the supply voltage and the CIB bus. The HW address is indicated on the label on the module.
Maintenance
Description The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected.
Notice Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!!
Warranty
Generally Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
Notice You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.

HW documentation

PDF

C-RI-0401S - Basic documentation

697.15 kB, (EN)

User manuals

PDF

Peripheral modules on the CIB Common Installation Bus(R) (en), TXV00413_02

13.94 MB, (EN, RU, DE, UA)

Files for designers

ZIP

Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.

20.49 MB
KNI

Foxtrot 2 - element library for SchemataCAD, v. 2024/01

6.79 MB

EC - Declaration of Conformity

PDF

Foxtrot - EC Declaration of conformity

295.20 kB, (EN, RU, DE, UA)
  • C-RI-0401S - The C-RI-0401S (order no TXN 133 47) is a combined module designed for a connection on the CIB bus. The module contains 2 universal analogue/binary inputs; it is possible to connect either passive resistive temperature sensors to them, or they can b...
  • C-RI-0401R - ...hes, sockets, etc.), the C-RI-0401R consists of two parts: The first part - the actual module (it corresponds with the C-RI-0401S module) - is placed in the flush box, which enables the connection to the CIB bus and provides processing of all c...
  • Measuring outdoor lighting, the sensor is installed by the customer - The outdoor lighting is measured by the C-RI-0401S module, whose built-in version is placed in the flush box; it is terminated with a connector, to which the BPW21 lighting sensor itself should be connected (it has to be ordered separately)....
  • Measuring the intensity of outdoor lighting - ...the lighting sensor, the module also includes a terminated outdoor temperature sensor. Inside the box is located the C-RI-0401S module, whose detailed description is given at the end of this manual, where the module C-RI-0401S is des...
  • Measuring the interior lighting - ...d by the C-RI-0401R-design module, which consists of two parts: The first, recessed part (corresponding to the C-RI-0401S ), is placed in the flush box, typically under the second wall-mounted design part. The second wall-mounted...
  • Measuring the lighting - ...cent spaces in the flat is 1:5.   The level of outdoor lighting and indoor illumination is measured by the C-RI-0401S module, or its variants, e.g. the C-RI-0401R-design, or the C-RI-0401I....
  • An IR transmitter and receiver to be mounted on the wall: the C-RI-0401R-design - ...le that goes through it to the second part of the module - the part with the bus (it is available separately, such as the C-RI-0401S ). The module is available in several designs; those based on the customer's special requirements are on...
  • Infrared (IR) control - ...des (IR transmission). It consists of the internal part (the electronics, the CIB connection) available separately as the C-RI-0401S , and the design part, which is implemented in accordance with the required design with a wall-mounted module wi...

No data available.