SX-1162TXN 111 62

SX-1162; ETH switch, 5x 10/100base TX; IEEE802.3, unmanaged

DI
DO
AI
AO
COM
SENSOR
Picture Variant Variant description
SX-1162
SX-1162; ETH switch, 5x 10/100base TX; IEEE802.3, unmanaged
Order num. TXN 111 62
Teco code TXN 111 62
Categories Communication - Ethernet
Tags -
Power supply
Module thermal/power loss 2 W
Maintenance
Description The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected.
Notice Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!!
Warranty
Generally Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
Notice You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.

HW documentation

PDF

SX-1162 - Basic documentation

100.22 kB, (CS, EN, RU, DE, UA)

Scheme

SX-1162

SX-1162

14.96 kB, (CS, EN, RU, DE)

Files for designers

ZIP

Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.

20.49 MB
KNI

Foxtrot 2 - element library for SchemataCAD, v. 2024/01

6.79 MB
  • SX-1162, an Ethernet switch on a DIN rail - The SX-1162 module includes a standard 5-port Ethernet switch. The ports are terminated with the  RJ-45 connectors and they support the 10Base-T and 100Base-TX interface (rate 10 or 100 Mbit). They are also equipped with the automatic cable cr...
  • TC800 CENTRAL MODULES - ...TH2 interfaces can be used to connect the ETCL bus, but only one of them at a time.If more than one module is connected, the SX-1162 module (five-port Ethernet switch) can be used for interconnection. It is recommended that all Ethernet switch module...
  • Power dissipation of modules for calculation of switchboard heating - ...IB 2x master CIB with power supply, for 64 slaves CF-1141 4,0 W TXN 111 62 SX-1162; ETH switch, 5x 10/100base TX; IEEE802.3, unmanaged SX-1162 2,0 W TXN 111 81...
  • Connecting multiple CF-2141s to a single CP-2005 - ...y located at the CF-2141  module), ev. on the total power consumption (if several CF-2141 together with CP-2xxx and SX-1162 are in one switchboard, it is possible to supply them from one common source).     Fig.1&n...
  • Control of Atrea recuperation units equipped with digital regulation - ...Tecomat systems are connected to ATREA heat recovery units via an Ethernet network. The switch used in the example is a SX-1162 DIN rail module....

No data available.