CP-8001TXN 180 01
CP-8001; CPU/1core, 2x ETH100/10, 2xUSB, 2x Slot for CH1-4, 128 kB Databox
DI | 16x DI |
---|---|
DO | |
AI | |
AO | |
COM | 2x ETH 10/100 4x Serial channel (2x free slot for MR-013x submodules) 1x USB device 1x USB host 1x TCL3 master (system bus) |
SENSOR |
Picture | Variant | Variant description |
---|---|---|
CP-8001 |
CP-8001 is a central module for the TC800 series containing 2x ETH100/10, 2x USB, 2x slot for serial channel submodules CH1-4, also 128 KB memory for DataBox, single-core processor ARMv7 792 MHz, no internal WLAN1 interface, integrated display size 13 x 7 mm.
Order num. | TXN 180 01 |
---|---|
Teco code | TXN 180 01 |
Categories | TC800 - Central modules |
Tags | - |
System parameters of the central unit | |
---|---|
Row of central unit | I |
User program memory | 1 MB |
Memory for user variables / including RETAIN variables | 320 kB/48 kB |
Instruction length | 4 Byte |
Backup of program source code in PLC | Yes, optional in Mosaic |
On-line program change in PLC | Yes, including I / O configuration change |
DataBox - additional internal data memory | 128/257 kB, optional |
File system - Internal Drive in PLC | 128 MB, journaling file system |
File system - RAM disk PLC | 16 MB |
File System - USB Flash Drive | Supported |
File system - Micro SD card | supported (except for variants with WLAN1) |
Optional memory card slot | microSD - Card Slot (<= 1TB) |
Cycle time per 1k of logic instructions | 0,036 ms |
Cycle time for 1k integer operations | 0,044 ms |
Cycle time for 1k floating point operations | 0,043 ms |
Development environment | Mosaic v2018.2 or higher |
Programming languages | ST, IL, LD, FBD, SFC, CFC |
RTC - Real time circuit | Yes |
RTC - Backup time | typ. 500 hours |
Integrated Web server | Yes |
Integrated Datalogger | Yes |
Access to PLC variables via web API | Yes |
COM - Communication - IP/Ethernet | |
Ethernet 10/100 Mb (ETHx) | 2 |
WLAN2 (external via USB host, optional) | 1 |
Available system modes on ETH and WLAN | UNI, PC, PLC, PLD |
TCP / IP protocol | Yes |
UDP protocol | Yes |
HTTPS protocol | Yes |
HTTP protocol | Yes |
WebSocket protocol | Yes |
Protocol MODBUS/TCP | Yes |
SMTP protocol | Yes |
IEC 60870-5-104 protocol | Yes |
REST API | Yes |
COM - USB | |
USB devices interface | 1x micro-USB |
USB host interface | 1x USB-A |
Available system modes on USB | PC |
COM - Serial channels | |
max. number of serial channels that can be serviced at one time | 10 |
max. number of optional serial channels in the basic module | 4 |
number of slots for optional submodules with interface (MR-013x) | 2 |
max. number of expanding serial channels on the TCL2 bus | 6 |
Communication options on submodules MR-0135 | PFB - Profibus DP (master) |
Available system modes on CH5-10 | UNI, CSJ (CAN) |
Modbus RTU / ASCII master protocol | Yes |
Modbus protocol RTU/ASCII slave | Yes |
COM - System buses | |
TCL3 - system I/O bus | 1x TCL3 master |
TCL3 - Range of one branch of the system I/O bus | max. 64 I/O modules |
The communication rate of the system I / O bus | 4 Mbps |
ITCL - internal system bus | Yes |
ITCL - number of exchangeable submodules | 2 |
ETCL - external system bus | 1 (ETH1 or ETH2) |
Power supply | |
Nominal supply voltage (V) | 24 V DC; Power supply from the system bus |
Supply voltage, tolerances | 20 - 30 V DC |
Module thermal/power loss | 1 W |
Maximum current consumption (mA) | < 50 mA |
Size and weight | |
Weight approx. | 140 g |
Product dimensions (width x height x depth) | 24 x 118 x 97 mm |
Operating conditions, product standards | |
Product standard | ČSN EN 61131-2:2008 (idt IEC 61131-2:2007) - Programmable control units |
Protection class of electrical object | III, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016) |
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) | IP20 |
Operating areas | Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005) |
Degree of pollution | 2, according to ČSN EN 60664-1 ed.2: 2008 (idt IEC 60664-1: 2007) |
Overvoltage category installation | II, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007) |
Type of device | Built-in |
Working position | Vertical |
Type of operation (operating frequency) | Continuous |
Ambient operating temperatures | -20 °C to + 55 °C |
Operating relative humidity | from 10 % up to 95 % without condensation |
Operating atmospheric pressure | min. 70 kPa (<3,000 m above sea level) |
Storage temperatures | –25 °C to +70 °C |
Storage relative humidity | Max. 80% without vapor condensation |
Storage environment | Dry, clean areas without conductive dust, aggressive gases or acid vapors for a period not exceeding the warranty period. |
Transport temperatures | -25°C to -70°C |
Transport environment | Covered means of transport, transport packaging must not be exposed to the effects of rain and snow |
Electromagnetic compatibility, Mechanical endurance | |
Electromagnetic compatibility / Emission | A, according to EN 55032 ed. 2: 2017 (idt CISPR 32: 2015) |
Emmisions - note | In premises where the use of radio and television receivers can be expected to be used a distance of 10 m from these devices may cause radio interference. In such a case, the user may be required to take appropriate action. |
Electromagnetic compatibility / Immunity | min. as required by EN 61131-2: 2007 |
Sinusoidal vibration endurance | 10 Hz to 57 Hz amplitude 0.075 mm, 57 Hz to 150 Hz acceleration 1 G, according to Fc according to ČSN EN 60068-2-6 ed.2:2008 (idt IEC 60068-2-6:2007), 10 cycles in each axis . |
Packaginng, transportation, storage | |
Description | The module is packed in a paper box. This documentation is also part of the package. The outer packaging is carried out according to the scope of the order and the method of transport in a transport package provided with labels and other data necessary for transport. The product must not be exposed to direct weather conditions during transport and storage. Malting of the product is only allowed in clean rooms without conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C |
Installation | |
Assembly description | The installation of the TC800 system module is carried out by sliding it perpendicularly onto the DIN rail ČSN EN 50022 with busbar and locking latch in the lower part of the module. A more detailed description and mechanical drawings with dimensions are given in the documentation TXV 004 72. |
Module operation | |
Module configuration | The module is operated, set up and diagnosed from the Mosaic development environment. |
Commissioning | On the module, the DIP switch in the left part of the case sets a unique address within one frame. The module is fully ready for operation after inserting it into the frame and turning on the power supply. |
Module diagnostics | The basic diagnostic system of the module is part of its standard software. It has been in operation since the module power was turned on and works independently of the user. Diagnosed error states of the module and connected peripheral modules of the assembly are signaled in the status word of the module and on the module panel |
Maintenance | |
Description | The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected. |
Notice | Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!! |
Warranty | |
Generally | Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s. |
Notice | You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change. |
HW documentation
CP-8001 - Basic documentation
1.70 MB, (EN)
Files for designers
TC800 - library of elements in DXF and DWG formats, v. 2024/01
487.65 kB
TC800 - element library for SchemataCAD, v. 2024/01
116.21 kB
EC - Declaration of Conformity
TC800 - CE declaration of conformity (cs)
292.20 kB
TC800 - CE Declaration of Conformity (en)
709.29 kB
- Central module CP-8001 - Central unit in module CP-8001 has series I. These units have the following features: • 1 MB of memory for user programs • 128 MB internal file system for project archiving, among others (chapter...
- Communication interface submodule connector on the CP-8001 module - ...internal bus of the base module. Modules MR-0130 to MR-0134 complement the serial communication channels on the basic module CP-8001. Optional submodules to the basic module, e.g. CP-8001 they mount on the right flank in the...
- TC800 power supply sizing calculation and heat loss - ...nbsp; CP-8001 TXN 180 01 2 2,0 W 0,0 W 2,0 W 2,0 W &nb...
- TC800 CENTRAL MODULES - ...e central module can be equipped with two submodules, eg with serial channels or other buses. The central unit in the CP-8001 module is described in the following article . Fig. 1. TC800 central module...
- TECOMAT TC800 SYSTEM FEATURES - ...TCL2, CIB, etc.) is given in the article CENTRAL MODULES TC800 . Basic overview of TC800 modules Central module CP-8001 Power supply modules PW-8901 and PW-8902 Binary input module IB-8302 Binary input module IB-8310...
No data available.