C-WG-0503R-LOGUS, white, TBRTXN 133 53.01LTBR
C-WG-0503R-T-LOGUS white; CIB, Interior RFID reader, 2x LED, 1x buzzer, 1x temperature sensor, 1x DI TTL
DI | 3x DI (5V TTL) 2x DI/AI see AI |
---|---|
DO | 3x DO (NPN) |
AI | 2x DI / AI see DI (R, binary, balanced) |
AO | Power output 12V / 60mA |
COM | 1x CIB slave 1x Wiegand |
SENSOR | 1x RFID |
Picture | Variant | Variant description |
---|---|---|
C-WG-0503R-LOGUS, white, TBR | Color: White | |
C-WG-0503R-LOGUS, ivory, TMF | Color: Ivory | |
C-WG-0503R-LOGUS, ice, TGE | Color: Ice | |
C-WG-0503R-LOGUS, Pearl, TPE | Color: Pearl | |
C-WG-0503R-LOGUS, aluminum, TAL | Color: Aluminum | |
C-WG-0503R-LOGUS, gray, TIS | Color: Grey | |
C-WG-0503R-T-LOGUS black | Color: Black | |
C-WG-0503R-T-LOGUS gold | Color: Gold |
C-WG-0503R-LOGUS; CIB, Interior RFID reader, 2x LED, 1x buzzer, 1x temperature sensor, 1x DI TTL
Order num. | TXN 133 53.01LTBR |
---|---|
Teco code | TXN 133 53.01LTBR |
Categories | CFox - LOGUS, Covers and devices |
Tags | - |
COM - Serial channels | |
---|---|
Wiegand protocol - format | 42 bits , 34bits , 26 bits , 40bits transparent |
Wiegand protocol - number of bytes | 5 , 4 , 3 , 5 |
COM - System buses | |
CIB - Common Installation Bus (R): Installation I/O bus | 1x CIB slave |
DI - Parameters of binary inputs DC (group A) | |
Parameters valid for inputs on the terminals | DI1-DI3 |
Number of inputs in group | 3 |
Common wire | +12V DC |
Input type | TTL 5V |
Galvanic separation of inputs from CIB bus | No |
Pull-up resistor | 3,9 kΩ |
DO - Parameters of binary transistor outputs (group A) | |
Parameters valid for the terminals | DO1-DO3 |
Number of transistor outputs | 3 |
Number of outputs in group | 3 |
Organization of transistor outputs into groups | 3 (DO1-DO3) |
Common group conductor | +12 V |
Output type | NPN open collector |
Galvanic separation from internal circuits | No |
Diagnostics | No |
Output voltage | 30 V DC, max., open collector NPN |
Output current | 30 mA |
AI - Organization of analog inputs | |
Total number of analog inputs | 2 |
Number of inputs per group | 2 |
Number of analog input groups | 1 |
Organization of analog inputs into groups | 2x (DI/AI4, DI/AI5) |
Input type | With common clamp |
Common wire | Minus |
Galvanic separation from internal circuits | No |
Diagnostics | overload signaling in status word |
Digital resolution | 10 bit |
AI - Analog Input Ranges (Group A) | |
Parameters valid for inputs on the terminals | DI/AI4, DI/AI5 |
Passive sensor | Pt1000, W100 = 1,385 (-90 to +400 ° C) |
Passive sensor | Pt1000, W100 = 1,391 (-90 to +400 ° C) |
Passive sensor | Ni1000, W100 = 1,500 (–60 to +200 ° C) |
Passive sensor | Ni1000, W100 = 1.617 (-60 to +200 ° C) |
Passive sensor | Resistance transmitter 0-160 kOhm |
Passive sensor | KTY81-121; PTC thermistor (-55 to + 125 °C) |
DI: Voltage-free contact | 0 when> 1.5 kOhm, 1 when <0.5 kOhm |
DI: Balanced resistance input | 2x 1k1 (tamper/0/1/tamper) |
Resistance measurement error - maximum error at 25 ° C | ± 0.5% of full scale |
Power supply | |
Supply voltage, tolerances | 24/27 V DC from CIB bus |
Power supply from CIB - typical current consumption (mA) | 20 mA |
Power supply from CIB - maximum current consumption (mA) | 85 mA |
Power supply from CIB - internal protection | No |
Internal auxiliary power supply - voltage | +12 V DC |
Internal auxiliary power supply - current max. | 60 mA |
Size and weight | |
Weight approx. | 75 g |
Product dimensions (width x height x depth) | 86 × 86 × 35mm |
Operating conditions, product standards | |
Product standard | ČSN EN 60730-1 ed. 2:2001 (mod IEC 60730-1:1999) |
Protection class of electrical object | III, according to ČSN EN 61140: 2003 (idt IEC 61140: 2001) |
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) | IP20 |
Operating areas | Normal according to ČSN 33 2000-1: 2003 (IEC 364-1: 1992 mod) |
Degree of pollution | 1, according to ČSN EN 60664-1: 2004 (mod IEC 60664-1: 1992) |
Overvoltage category installation | II, acc. ČSN EN 60664-1:2004 (mod IEC 606641:1992) |
Type of device | In the installation box, under the cover |
Working position | Any |
Type of operation (operating frequency) | Continuous |
Ambient operating temperatures | 0 ° C to + 55 ° C |
Operating temperature maximum (° C) | +55°C |
Operating temperature minimum (° C) | 0°C |
Operating relative humidity | from 10 % up to 95 % without condensation |
Storage temperatures | –25 °C to +70 °C |
Electromagnetic compatibility, Mechanical endurance | |
Electromagnetic compatibility / Emission | B, according to EN 55022: 1999 (mod CISPR22: 1997) |
Electromagnetic compatibility / Immunity | min. according to ČSN EN 60730-1 ed.2: 2001 |
Sinusoidal vibration endurance | 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.) |
Installation | |
Assembly description | Indoor wall mounting |
Connection | |
Warning | All external circuits connected to the module must meet the conditions for SELV circuits! |
Connection of power and system communication | Loose wires in the connector / 0.15-0.5 mm2 |
Connection of inputs / outputs | Loose wires in the connector / 0.15-0.5 mm2 |
Module operation | |
Commissioning | The module is operated, set and diagnosed from the MOSAIC programming environment or other parameterization software. The module is ready for operation after connecting the supply voltage and the CIB bus. The HW address is indicated on the label on the module. |
Module diagnostics | The basic diagnostics is performed internally and the result is available in the relevant registers of the Mosaic environment. |
Maintenance | |
Description | The module does not require any maintenance under general installation conditions. |
Notice | Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!! |
Warranty | |
Generally | Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s. |
Notice | You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change. |
User manuals
Peripheral modules on the CIB Common Installation Bus(R) (en), TXV00413_02
13.94 MB, (EN, RU, DE, UA)
Files for designers
Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.
20.49 MB
Foxtrot 2 - element library for SchemataCAD, v. 2024/01
6.79 MB
EC - Declaration of Conformity
Foxtrot - EC Declaration of conformity
295.20 kB, (EN, RU, DE, UA)
No data available.
No data available.