C-RC-0003R-Time, ivory / ice whiteTXN 133 37.Ti21

C-RC-0003R-Time; CIB, Wall controller with LCD-HL1, 3 buttons, temperature and humidity sensor; ivory / ice white

DI 1x DI/AI
3x Button
DO
AI 1x DI / AI see DI
AO
COM 1x LCD graphic 98x64px
SENSOR 1x Temperature
1x Humidity
Picture Variant Variant description
C-RC-0003R-Time, white / ice white Color: White / Ice white
C-RC-0003R-Time, white / white Color: White / White
C-RC-0003R-Time, white / ice gray Color: White / Ice gray
C-RC-0003R-Time, titanium Color: Titanium
C-RC-0003R-Time, ivory / ice white Color: Ivory / ice white
C-RC-0003R-Time, coffee / ice opal Color: Coffee / ice opal
C-RC-0003R-Time, lungo / milky white Color: Lungo / milky white
C-RC-0003R-Time, antique silver Color: Old silver
C-RC-0003R-Time, champagne Color: Champagne
C-RC-0003R-Time, anthracite Color: Anthracite
C-RC-0003R-Time, steel Color: Steel
C-RC-0003R-Time; CIB, Wall controller with LCD-HL1, 3 buttons, temperature and humidity sensor; white / ice white
Order num. TXN 133 37.Ti21
Teco code TXN 133 37.Ti21
Categories CFox - Time, Covers and devices
Tags -
COM - System buses
CIB - Common Installation Bus (R): Installation I/O bus 1x CIB slave
AI - Analog Input Ranges (Group A)
Parameters valid for inputs on the terminals DI/AI1
Passive sensor Pt1000, W100 = 1,385 (-90 to +400 ° C)
Passive sensor Pt1000, W100 = 1,391 (-90 to +400 ° C)
Passive sensor Ni1000, W100 = 1,500 (–60 to +200 ° C)
Passive sensor Ni1000, W100 = 1.617 (-60 to +200 ° C)
Passive sensor Resistance transmitter 0-160 kOhm
Passive sensor KTY81-121; PTC thermistor (-55 to + 125 °C)
Passive sensor NTC Thermistor 12k / 25 °C (-40 to + 125 °C)
DI: Voltage-free contact 0 when> 1.5 kOhm, 1 when <0.5 kOhm
DI: Balanced resistance input 2x 1k1 (tamper/0/1/tamper)
Resistance measurement error - maximum error at 25 ° C ± 0.5% of full scale
Power supply
Supply voltage, tolerances 24/27 V DC from CIB bus
Power supply from CIB - typical current consumption (mA) 10 mA
Power supply from CIB - maximum current consumption (mA) 17 mA
Internal protection No
Size and weight
Weight approx. 75 g
Product dimensions (width x height x depth) 86 × 86 × 35 mm
Operating conditions, product standards
Product standard ČSN EN 60730-1 ed. 2:2001 (mod IEC 60730-1:1999)
Protection class of electrical object III, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) IP20
Operating areas Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution 1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007)
Overvoltage category installation II, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of device In the installation box on the wall
Working position Any
Type of operation (operating frequency) Continuous
Ambient operating temperatures 0 ° C to + 55 ° C
Operating relative humidity from 10 % up to 95 % without condensation
Operating atmospheric pressure min. 70 kPa (<3,000 m above sea level)
Storage temperatures –25 °C to +70 °C
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / Emission B, according to EN 55032 ed. 2: 2017 (idt CISPR 32: 2015)
Electromagnetic compatibility / Immunity min. according to ČSN EN 60730-1 ed.2: 2001
Sinusoidal vibration endurance 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.)
Connection
Connection description An example of module connection is shown in the following figure.
Connection of inputs / outputs terminal block with spring clamp 0.15-0.5 mm2, push-in
Module operation
Module configuration The module is operated, set and diagnosed from the programming
MOSAIC or FoxTool environment.
For more information, see the Bus Peripherals module
CIB TXV 004 13.
Module diagnostics The basic diagnostics is performed internally and the result is available in the relevant registers of the Mosaic environment.
Maintenance
Description The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected.
Notice Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!!
Warranty
Generally Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
Notice You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.

HW documentation

PDF

C-RC-0003R_U01 Basic Documentation

113.29 kB

User manuals

PDF

Peripheral modules on the CIB Common Installation Bus(R) (en), TXV00413_02

13.94 MB, (EN, RU, DE, UA)

Files for designers

ZIP

Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.

20.49 MB
KNI

Foxtrot 2 - element library for SchemataCAD, v. 2024/01

6.79 MB

EC - Declaration of Conformity

PDF

Foxtrot - EC Declaration of conformity

295.20 kB, (EN, RU, DE, UA)

No data available.

No data available.