C-RC-0002R-Time, white / whiteTXN 133 33.Ti03

C-RC-0002R-Time; CIB, Wall controller with LCD1, 3 buttons, temperature sensor, white / white

DI 3x Button
DO 1x green LED
AI 1x AI
AO
COM 1x CIB slave
1x LCD display
SENSOR 1x internal temperature
Picture Variant Variant description
C-RC-0002R-Time, white / ice white Color: White / Ice white
C-RC-0002R-Time, white / white Color: White / White
C-RC-0002R-Time, white / ice gray Color: White / Ice gray
C-RC-0002R-Time, titanium Color: Titanium
C-RC-0002R-Time, ivory / ice white Color: Ivory / ice white
C-RC-0002R-Time, coffee / ice opal Color: Coffee / ice opal
C-RC-0002R-Time, lungo / milky white Color: Lungo / milky white
C-RC-0002R-Time, antique silver Color: Old silver
C-RC-0002R-Time, champagne Color: Champagne
C-RC-0002R-Time, anthracite Color: Anthracite
C-RC-0002R-Time, steel Color: Steel
C-RC-0002R-Time; CIB, Wall controller with LCD1, 3 buttons, temperature sensor, white / ice white
Order num. TXN 133 33.Ti03
Teco code TXN 133 33.Ti03
Categories CFox - Time, Covers and devices
Tags -
COM - System buses
CIB - Common Installation Bus (R): Installation I/O bus 1x CIB slave
AI - Analog Input Ranges (Group A)
Parameters valid for inputs on the terminals +IN, -IN
Passive sensor Resistance transmitter 0-100 kOhm
Passive sensor NTC Thermistor 5k / 25 °C (–40 to + 125 °C)
Passive sensor NTC Thermistor 10k / 25 °C (-40 to + 125 °C)
Passive sensor NTC Thermistor 12k / 25 °C (-40 to + 125 °C)
Passive sensor NTC Thermistor 15k / 25 °C (-40 to + 125 °C)
Passive sensor NTC Thermistor 20k / 25 °C (-40 to + 125 °C)
Parameter des Temperatursensors
Temperature - Description of measurements Main analog input = Internal sensor temperature
Additional analog input = External sensor temperature (according to the sensor used)
Temperature - Sensor type Pt1000
Temperature - Measurement range 0°C ÷ 50°C
Temperature - Resolution 0,1 °C
Temperature - Measurement accuracy typ. ±0,5 °C
Power supply
Supply voltage, tolerances 24/27 V DC from CIB bus
Maximum power input < 0,5 W
Galvanic separation of power supply from internal circuits No
Size and weight
Weight approx. 75 g
Product dimensions (width x height x depth) 83 x 81 x 25 mm
Operating conditions, product standards
Product standard ČSN EN 60730-1 ed. 2:2001 (mod IEC 60730-1:1999)
Protection class of electrical object III, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) IP20
Operating areas Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution 1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007)
Overvoltage category installation II, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of device In the installation box on the wall
Working position Any
Type of operation (operating frequency) Continuous
Ambient operating temperatures 0 °C to + 55 °C
Operating relative humidity from 10 % up to 95 % without condensation
Operating atmospheric pressure min. 70 kPa (<3,000 m above sea level)
Storage temperatures –25 °C to +70 °C
Packaginng, transportation, storage
Description The module is packed in a paper box. This documentation is also part of the package. The outer packaging is carried out according to the scope of the order and the method of transport in a transport package provided with transport labels and other data necessary for transport.

Transport from the manufacturer is carried out in the manner agreed upon when ordering. The transport of the product by the customer's own means must be carried out by covered means of transport, in the position specified by the label on the packaging. The box must be stored in such a way that it does not move spontaneously and the outer packaging is not damaged.

The product must not be exposed to direct weather conditions during transport and storage. Transport is permitted at temperatures of -25 ° C to 70 ° C, relative humidity of 10% to 95% (non-condensing) and a minimum atmospheric pressure higher than 70 kPa.

The product may only be stored in clean rooms free of conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C.
Installation
Assembly description The sensor module is mounted in the installation box using a mounting fitting. When mounting and positioning the sensor module, it is necessary to ensure that the operating conditions are observed during its subsequent operation.
Connection
Connection description The module is implemented as a standard unit on a two-wire CIB bus, which ensures communication and power supply of the entire sensor. The bus wires are connected to the wires that are routed on the tube module (for marking, see Fig. 1).

The CIB bus can have any topology and branching up to a distance of 500 m and up to 32 units on one CIB branch. The CIB bus master is the basic PLC unit TECOMAT FOXTROT or an external CIB bus master, eg the CF-1141 module. Further information can be found in the manual Peripheral modules on the CIB TXV 004 13.
Connection of power and system communication Ribbon flat conductors 0.15 / 0.5 mm2
Module operation
Module configuration SW configuration, operation and diagnostics of the C-RC-0002R module are performed from the MOSAIC programming environment.

Notice:
Improper connection of the terminals and setting of the jumpers may damage the module.
Commissioning The module does not require any maintenance if the general conditions for installation are observed. Operations that require the module to be assembled or disassembled are always performed with the CIB power off.
Maintenance
Instructions The module does not require any maintenance if the general conditions for installation are observed. Operations that require installation or a module are always performed with the CIB power off.
Warranty
Generally Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
Notice You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.

HW documentation

PDF

C-RC-0002R - Basic documentation

407.91 kB

User manuals

PDF

Peripheral modules on the CIB Common Installation Bus(R) (en), TXV00413_02

13.94 MB, (EN, RU, DE, UA)

Files for designers

ZIP

Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.

20.49 MB
KNI

Foxtrot 2 - element library for SchemataCAD, v. 2024/01

6.79 MB

EC - Declaration of Conformity

PDF

Foxtrot - EC Declaration of conformity

295.20 kB, (EN, RU, DE, UA)

No data available.

No data available.