C-WS-0200R-LogusTXN 133 56
C-WS-0200R-Logus; CIB, Wall switch button, 2x buttons, 1x LED red/green, 2x AI/DI, 1x internal temperature
DI | 2x AI/DI |
---|---|
DO | 1x green LED 1x LED red |
AI | 2x AI / DI see DI |
AO | |
COM | 1x CIB slave |
SENSOR | 1x temperature |
Picture | Variant | Variant description |
---|---|---|
C-WS-0200R-Logus |
C-WS-0200R-Logus is a controller
- with 2 short-way buttons
- with red and green LED signaling
- with 1x internal temperature sensor
Order num. | TXN 133 56 |
---|---|
Teco code | TXN 133 56 |
Categories | CFox - LOGUS, Covers and devices |
Tags | - |
COM - System buses | |
---|---|
CIB - Common Installation Bus (R): Installation I/O bus | 1x CIB slave |
DI - Organization of binary inputs | |
Total number of binary inputs | 2 |
Number of groups of binary inputs | 1 |
Organization of binary inputs into groups | 2x AI/DI (DI/AI1, DIAI2) |
DI - Parameters of binary inputs DC (group A) | |
Input type | microswitch button |
DO/RO - Organization of binary outputs | |
Organization of binary outputs into groups |
1x green LED 1x red LED |
AI - Analog Input Ranges (Group A) | |
Voltage | 0-2 V |
Passive sensor | Pt1000, W100 = 1,385 (-90 to +400 ° C) |
Passive sensor | Pt1000, W100 = 1,391 (-90 to +400 ° C) |
Passive sensor | Ni1000, W100 = 1,500 (–60 to +200 ° C) |
Passive sensor | Ni1000, W100 = 1.617 (-60 to +200 ° C) |
Passive sensor | Resistance transmitter 0-100 kOhm |
Passive sensor | KTY81-121; PTC thermistor (-55 to + 125 °C) |
Passive sensor | NTC Thermistor 12k / 25 °C (-40 to + 125 °C) |
DI: Voltage-free contact | 0 when> 1.5 kOhm, 1 when <0.5 kOhm |
Temperature measurement error | ± 1°C |
AI recovery period | 5 s typically |
Parameter des Temperatursensors | |
Temperature - Sensor type | NTC 12k |
Temperature - Measurement range | -10 ÷ +55 °C |
Temperature - Settling time | 150 min. |
Power supply | |
Supply voltage, tolerances | 24/27 V DC from CIB bus |
Maximum power input | < 0,5 W |
Power supply from CIB - typical current consumption (mA) | 15 mA |
Power supply from CIB - Galvanic separation of power supply from internal circuits | No |
Internal protection | No |
Size and weight | |
Weight approx. | 75 g |
Product dimensions (width x height x depth) | 86 × 86 × 38 mm |
Operating conditions, product standards | |
Product standard | ČSN EN 60730-1 ed.4 :2017 (EN 60730-1:2016) -Automatic electronic control device (for household and similar purposes) |
Protection class of electrical object | II, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016) |
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) | IP10B |
Operating areas | Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005) |
Degree of pollution | 1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007) |
Type of device | On the wall |
Working position | Vertical |
Type of operation (operating frequency) | Continuous |
Ambient operating temperatures | -10 °C to + 55 °C |
Operating relative humidity | from 10 % up to 95 % without condensation |
Operating atmospheric pressure | min. 70 kPa (<3,000 m above sea level) |
Storage temperatures | –25 °C to +70 °C |
Electromagnetic compatibility, Mechanical endurance | |
Electromagnetic compatibility / Emission | B, according to EN 55022: 1999 (mod CISPR22: 1997) |
Electromagnetic compatibility / Immunity | min. according to ČSN EN 60730-1 ed.2: 2001 |
Sinusoidal vibration endurance | 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.) |
Packaginng, transportation, storage | |
Description | The module is packed in a paper box. This documentation is also part of the package. The outer packaging is carried out according to the scope of the order and the method of transport in a transport package provided with labels and other data necessary for transport. The product must not be exposed to direct weather conditions during transport and storage. Malting of the product is only allowed in clean rooms without conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C |
Installation | |
Assembly description |
The sensor module is mounted in a vertical position on a standard installation box with a spacing of fixing screws of 60 mm. Method: 1. Connect the wires to the next wiring 2. Screw the switch module to the installation box (pay attention to the position) 3. Click the box 4. Slide on and snap the fingerboard |
Connection | |
Connection description | The controller with short-path control with the possibility of connecting external sensors is implemented as a standard unit on a two-wire CIB bus, which ensures communication and power supply of the entire sensor. The CIB bus can have any topology and branching up to a distance of 500 m and up to 32 units on one CIB branch. The CIB bus master is the basic unit FOXTROT or an external module, for example CF-1141. Further information can be found in the manual “Peripheral modules on the CIB bus” TXV 004 13. |
Connection of power and system communication | terminal block with screw terminal 1.5 mm2 |
Connection of inputs / outputs | terminal block with screw terminal 1.5 mm2 |
Module operation | |
Commissioning | The module is operated, set and diagnosed from the MOSAIC programming environment or other parameterization software. The module is ready for operation after connecting the supply voltage and the CIB bus. The HW address is indicated on the label on the module. |
Module diagnostics | The basic diagnostics is performed internally and the result is available in the relevant registers of the Mosaic environment |
Maintenance | |
Description | The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected. |
Instructions |
The module does not require any maintenance if the general conditions for installation are observed. The tasks that require the module to be assembled or disassembled are always performed with the CIB bus switched off. Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures. |
Notice | Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!! |
Warranty | |
Generally | Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s. |
Notice | You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change. |
HW documentation
C-WS-0200R-Logus - Basic documentation
122.10 kB
User manuals
Peripheral modules on the CIB Common Installation Bus(R) (en), TXV00413_02
13.94 MB, (EN, RU, DE, UA)
Files for designers
Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.
20.49 MB
Foxtrot 2 - element library for SchemataCAD, v. 2024/01
6.79 MB
EC - Declaration of Conformity
Foxtrot - EC Declaration of conformity
295.20 kB, (EN, RU, DE, UA)
- C-WS-0x00R-Logus - Controllers in Logus design on the CIB bus are available in two versions: The C-WS-0200R-Logus with one fingerboard (2 push-buttons – up and down). The C-WS-0400R-Logus with two fingerboards (4 push-buttons – each fingerboard has a...
- Controllers on the CIB bus, the Logus design - You can control the lighting, blinds, ventilation and similar applications using the control unit C-WS-0200R-Logus with one fingerboard (2 buttons - one at the top and one below), or the C-WS-0400R-Logus with two fingerboards (4 buttons...
No data available.