Frame RM-8941 (14x 12mm)TXN 189 40

RM-8940; Frame for 10 positions (module 12 mm)

Frames of the RM-894x series form the supporting basis of all TECOMAT TC800 PLC assemblies.
  • It consists of a DIN rail according to ČSN EN 60715 with a width of 35 mm and a depth of 7.5 mm, into which the system bus is inserted.
  • The frames contain an eight-conductor system bus in an open design without connectors and are supplied in five dimensional variants.
  • It is inserted into the DIN rail and secured using handles on both ends of the frame.
  • The individual modules can then be mounted on the bus in any location with the exception of the frame mounting area.
  • The bus modules are mechanically fixed to the DIN rail using latches integrated into the housing of each module.
Order num. TXN 189 40
Teco code TXN 189 40
Categories TC800 - PLC frames
Tags -
Power supply
Nominal supply voltage (V) The bus part is passive and serves to distribute the 24 V DC power supply for the system and separately for the I/O part of the installed modules.
Operating conditions, product standards
Product standard ČSN EN 61131-2:2008 (idt IEC 61131-2:2007) - Programmable control units
Protection class of electrical object II, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) IP20
Operating areas Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution 1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007)
Overvoltage category installation II, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of device Built-in
Working position Vertical
Type of operation (operating frequency) Continuous
Ambient operating temperatures -20 °C to + 55 °C
Operating relative humidity from 10 % up to 95 % without condensation
Operating atmospheric pressure min. 70 kPa (<3,000 m above sea level)
Storage temperatures –25 °C to +70 °C
Storage relative humidity Max. 80% without vapor condensation
Storage environment Dry, clean areas without conductive dust, aggressive gases or acid vapors for a period not exceeding the warranty period.
Transport temperatures -25°C to -70°C
Transport environment Covered means of transport, transport packaging must not be exposed to the effects of rain and snow
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / Emission A, according to EN 55032 ed. 2: 2017 (idt CISPR 32: 2015)
Sinusoidal vibration endurance 10 Hz to 57 Hz amplitude 0.075 mm, 57 Hz to 150 Hz acceleration 1 G, according to Fc according to ČSN EN 60068-2-6 ed.2:2008 (idt IEC 60068-2-6:2007), 10 cycles in each axis .
Packaginng, transportation, storage
Description The module is packed in a paper box. This documentation is also part of the package. The outer packaging is carried out according to the scope of the order and the method of transport in a transport package provided with labels and other data necessary for transport. The product must not be exposed to direct weather conditions during transport and storage. Malting of the product is only allowed in clean rooms without conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C
Installation
Assembly description The frame contains the system bus in an open design without connectors and is supplied in five dimensional variants. It is inserted into the DIN rail and secured using handles on both ends of the frame. The individual modules can then be mounted on the bus in any location with the exception of the frame mounting area. The modules are mechanically fixed to the DIN rail using latches integrated into the housing of each module.
Covering the unoccupied part of the bus
Covers are available for covering the unoccupied part of the bus on the frame (covering the freely accessible electrical part of the bus), which are supplied in a combined set of 8 pieces with a cover width of 10 mm (Fig. 2.4). The required number of covers is broken off and snapped onto the DIN rail via the covered bus. The kit order number is TXN 189 60.
Module operation
Module configuration The bus part does not require any configuration or setup
Commissioning The bus part does not require any additional steps for commissioning
Maintenance
Description The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected.
Warranty
Generally Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
Notice You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.

Files for designers

ZIP

TC800 - library of elements in DXF and DWG formats, v. 2024/01

487.65 kB
KNI

TC800 - element library for SchemataCAD, v. 2024/01

116.21 kB

EC - Declaration of Conformity

PDF

TC800 - CE declaration of conformity (cs)

292.20 kB
PDF

TC800 - CE Declaration of Conformity (en)

709.29 kB

No data available.

No data available.