OS-8401TXN 184 01
OS-8401; 16x DO, GO, 24 V DC, CP, 0.5 A, transistor
DI | |
---|---|
DO | 16x DO |
AI | |
AO | |
COM | 1x TCL3 |
SENSOR |
Picture | Variant | Variant description |
---|---|---|
OS-8401 |
The OS-8401 peripheral module contains 16 transistor outputs with a maximum load of 0.5 A per output. The module is galvanically isolated from other PLC circuits.
The module is equipped with a screwless removable connector of 17 terminals with locking after insertion into the module.
The output circuits of the module require a 24 V DC power supply, which is connected (alone or together with the main power supply) to the power supply module of the PLC assembly.
The module is equipped with a screwless removable connector of 17 terminals with locking after insertion into the module.
The output circuits of the module require a 24 V DC power supply, which is connected (alone or together with the main power supply) to the power supply module of the PLC assembly.
Order num. | TXN 184 01 |
---|---|
Teco code | TXN 184 01 |
Categories | TC800 - I / O expansion modules |
Tags | - |
COM - System buses | |
---|---|
TCL3 - system I/O bus | 1x TCL3 slave |
DO - Parameters of binary transistor outputs (group A) | |
Parameters valid for the terminals | DO0 - DO15 |
Number of transistor outputs | 16 |
Number of output groups | 1 |
Number of outputs in group | 16 |
Organization of transistor outputs into groups | 16x (DO0-DO15) |
Common group conductor | VDO+ |
Output type | transistor output |
Galvanic separation from internal circuits | Yes |
Diagnostics | indication of energized output by LED on module panel |
Switching voltage | 20 – 30V DC |
Minimum voltage of the switched-off output (Vcl) | VVDO+ - 47V |
Switching current, output load | 0.5 A max, up to 4 outputs can be connected in parallel to achieve a higher output current. Outputs combined into 1 signal must always be from the same eight (from group 0-7 or 8-15) |
Group current | 8 A max. |
Switching time | 400 μs max. |
Opening time | 400 μs max. |
Residual current | 70 μA max. |
Short circuit protection | Yes |
Short-circuit current limitation | typ. 1.1 A |
Treatment of inductive load |
internal: 0.6J max (each output) external - RC element, diode The module can switch an inductive load without external protection if the energy stored in it does not exceed the specified value. Otherwise, you need to use external protection sized so that when the load is turned off, the voltage at the output does not fall below Vcl, i.e. ‑23V in the case of power supply VVDO+ = +24 V. |
Reverse polarity protection | Yes - The circuit will be inactive, the loads will be closed, current will flow through the protection diodes of the circuit. |
Initial peak current limitation | typ. 1.4 A |
Power supply | |
Supply voltage UVM, UVIO, nominal value | 24 V DC |
Supply voltage UVM, UVIO, allowed range | 20 - 30 V DC |
IVM supply current at UVM = 24 V | 8 mA |
Max. power consumption at the VM level | 0,2 W |
Module thermal/power loss | 1,8 W |
Galvanic separation of power supply from internal circuits | Yes |
Galvanic separation of power supply from peripheral circuits | No, power to the output circuits from VDO+ is terminated via the system bus and the system power supply module (terminal VIO-). |
Size and weight | |
Weight approx. | 85 g |
Product dimensions (width x height x depth) | 12 x 118 x 97 mm |
Operating conditions, product standards | |
Product standard | ČSN EN 61131-2:2008 (idt IEC 61131-2:2007) - Programmable control units |
Protection class of electrical object | III, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016) |
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) | IP20 |
Operating areas | Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005) |
Degree of pollution | 2, according to ČSN EN 60664-1 ed.2: 2008 (idt IEC 60664-1: 2007) |
Overvoltage category installation | II, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007) |
Type of device | Built-in |
Working position | Vertical |
Type of operation (operating frequency) | Continuous |
Ambient operating temperatures | -20 °C to + 55 °C |
Operating relative humidity | from 10 % up to 95 % without condensation |
Operating atmospheric pressure | min. 70 kPa (<3,000 m above sea level) |
Storage temperatures | –25 °C to +70 °C |
Storage relative humidity | Max. 80% without vapor condensation |
Storage environment | Dry, clean areas without conductive dust, aggressive gases or acid vapors for a period not exceeding the warranty period. |
Transport temperatures | -25°C to -70°C |
Transport environment | Covered means of transport, transport packaging must not be exposed to the effects of rain and snow |
Electromagnetic compatibility, Mechanical endurance | |
Electromagnetic compatibility / Emission | A, according to EN 55032 ed. 2: 2017 (idt CISPR 32: 2015) |
Emmisions - note | In premises where the use of radio and television receivers can be expected to be used a distance of 10 m from these devices may cause radio interference. In such a case, the user may be required to take appropriate action. |
Electromagnetic compatibility / Immunity | min. as required by EN 61131-2: 2007 |
Sinusoidal vibration endurance | 10 Hz to 57 Hz amplitude 0.075 mm, 57 Hz to 150 Hz acceleration 1 G, according to Fc according to ČSN EN 60068-2-6 ed.2:2008 (idt IEC 60068-2-6:2007), 10 cycles in each axis . |
Packaginng, transportation, storage | |
Description | The module is packed in a paper box. This documentation is also part of the package. The outer packaging is carried out according to the scope of the order and the method of transport in a transport package provided with labels and other data necessary for transport. The product must not be exposed to direct weather conditions during transport and storage. Malting of the product is only allowed in clean rooms without conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C |
Installation | |
Assembly description | The installation of the TC800 system module is carried out by sliding it perpendicularly onto the DIN rail ČSN EN 50022 with busbar and locking latch in the lower part of the module. A more detailed description and mechanical drawings with dimensions are given in the documentation TXV 004 72. |
Connection | |
Warning | All external circuits connected to the module must meet the conditions for SELV circuits! |
Power connection | Via system bus + I/O connector |
Connection of inputs / outputs | Connector with screwless terminals 0.2 ~ 1.5 mm2 |
Connector coding | The connector can be provided with a code to prevent its insertion into another type of module. Modules with connectors are delivered without coding, coding elements can be ordered separately. |
Connection description | An example of module connection is shown in the following figure. |
Module operation | |
Module configuration | The module is operated, set up and diagnosed from the Mosaic development environment. |
Commissioning | On the module, the DIP switch in the left part of the case sets a unique address within one frame. The module is fully ready for operation after inserting it into the frame and turning on the power supply. |
Module diagnostics | The basic diagnostic system of the module is part of its standard software. It has been in operation since the module power was turned on and works independently of the user. Diagnosed error states of the module and connected peripheral modules of the assembly are signaled in the status word of the module and on the module panel |
Maintenance | |
Description | The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected. |
Notice | Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!! |
Warranty | |
Generally | Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s. |
Notice | You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change. |
HW documentation
OS-8401 - Basic documentation
1.27 MB, (EN)
Files for designers
TC800 - library of elements in DXF and DWG formats, v. 2024/01
487.65 kB
TC800 - element library for SchemataCAD, v. 2024/01
116.21 kB
EC - Declaration of Conformity
TC800 - CE Declaration of Conformity (en)
709.29 kB
TC800 - CE declaration of conformity (cs)
292.20 kB
- Binary output module OS-8401 - The binary output module OS-8401 contains 16 transistor outputs, max. 0.5 A per output. The outputs are organized into one group of 16. The module is galvanically separated from other PLC circuits. The outputs are realized by semiconductor switche...
- Examples of power connections for TC800 modules - ...ot be connected with an external wire (an unwanted ground loop would occur) The internal circuits of the outputs of the OS-8401 module are powered from the VIO level (terminals A3 and A4 of the PW-8901 module), terminal A1 on the OS-8401 module...
- TC800 power supply sizing calculation and heat loss - ...nbsp; OS-8401 TXN 184 01 1 0,2 W 0,0 W 1,8 W 1,8 W OS-...
- TECOMAT TC800 SYSTEM FEATURES - ...pply modules PW-8901 and PW-8902 Binary input module IB-8302 Binary input module IB-8310 Binary output module OS-8401 Binary output module OS-8402 Binary output module OS-8410 Binary output module OR-8450 TC800 syst...
No data available.