C-IT-0500ITXN 143 39

C-IT-0500I; CIB, 5x AI, IP65

DI 4x DI
DO
AI 5x AI
AO
COM 1x CIB slave
SENSOR
Picture Variant Variant description
C-IT-0500I
Module with 4 universal AI/DI inputs and one current input 0 - 20 mA / 4 - 20mA.
Order num. TXN 143 39
Teco code TXN 143 39
Categories CFox - Outdoor modules, IP54 / 65
Tags IP-65
COM - System buses
CIB - Common Installation Bus (R): Installation I/O bus 1x CIB slave
DI - Organization of binary inputs
Total number of binary inputs 4
Number of groups of binary inputs 1
Organization of binary inputs into groups 4x DI (DI/AI1 - DI/AI4)
DI - Parameters of binary inputs DC (group A)
Parameters valid for inputs on the terminals 4x DI/AI1 - DI/AI4
Number of inputs in group 4
Common wire GND - module ground
Combined input type DI/AI Active, for sensing potential-free contacts and measuring resistance sensors
Galvanic isolation of inputs from internal/peripheral circuits No
Delay from log. 0 to log. 1 200 μs
Delay from log. 1 to log. 0 200 μs
Max. measuring voltage on the connected contact 3,5 V DC
Internal input resistance 2 kΩ
Max. resistance for closed contact, log. 1 < 0,5 kΩ
Min. resistance for open contact, log. 0 > 4,7 kΩ
AI - Organization of analog inputs
Total number of analog inputs 5
Number of inputs per group 5
Number of analog input groups 1
Organization of analog inputs into groups 3x DI (DI/AI1 - DI/AI3)
Input type 4x AI/DI combined
1x AI current input (AI5)
Common wire GND terminal
Galvanic separation from internal circuits No
Diagnostics overload signaling in status word
Digital resolution 12 bit
AI - Analog Input Ranges
Parameters valid for inputs on the terminals DI/AI1 - DI/AI4
Voltage 0-2 V
Passive sensor Pt1000, W100 = 1,385 (-90 to +400 ° C)
Passive sensor Pt1000, W100 = 1,391 (-90 to +400 ° C)
Passive sensor Ni1000, W100 = 1,500 (–60 to +200 ° C)
Passive sensor Ni1000, W100 = 1.617 (-60 to +200 ° C)
Passive sensor Resistance transmitter 0-100 kOhm
Passive sensor KTY81-121; PTC thermistor (-55 to + 125 °C)
Passive sensor NTC Thermistor 10k / 25 °C (-40 to + 125 °C)
Passive sensor NTC Thermistor 12k / 25 °C (-40 to + 125 °C)
AI - Analog Input Ranges (Group A)
Parameters valid for inputs on the terminals AI5
Ccurrent 0 - 20 mA
Current 4-20 mA
Power supply
Supply voltage, tolerances 24/27 V DC from CIB bus
Typical power input 0,3 W
Maximum power input 0,42 W
Power supply from CIB - maximum current consumption (mA) 15 mA
Size and weight
Weight approx. 140 g
Product dimensions (width x height x depth) 65 × 100 × 40 mm
Operating conditions, product standards
Product standard ČSN EN 60730-1 ed.4 :2017 (EN 60730-1:2016) -Automatic electronic control device (for household and similar purposes)
Protection class of electrical object III, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) IP65
Operating areas Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution 1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007)
Overvoltage category installation III, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of device Outdoor
Working position Vertical (grommets down)
Ambient operating temperatures –25 °C až +75 °C
Operating atmospheric pressure min. 70 kPa (<3,000 m above sea level)
Storage temperatures –25 ° C to + 85 ° C
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / Emission ČSN EN 55022 ed2:2007 (mod CISPR22:2005)
Electromagnetic compatibility / Immunity min. according to ČSN EN 60730-1 ed.2: 2001
Sinusoidal vibration endurance 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.)
Packaginng, transportation, storage
Description The module is packed in a cardboard box. The outer packaging is carried out according to the scope of the order and the method of transport in a transport container provided with labels and other information necessary for transport. Transport from the manufacturer is carried out in the manner agreed upon when ordering. Transport of the product by the customer's own means must be carried out by covered means of transport, in the position specified by the label on the packaging. The box must be stored in such a way as to prevent spontaneous movement and damage to the outer packaging. The product must not be exposed to direct weather conditions during transport and storage. The product is only allowed to be stored in clean rooms without conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20°C
Installation
Assembly description The module is mounted vertically on the support surface with the cable gland facing downwards. The assembly (basic module and possibly peripheral modules) is installed according to TXV 004 13.
Connection
Connection of power and system communication 2 wire cable 4.5 - 7mm, PG9 bushing
Connection of power and system communication terminal block with spring clamp 0.2-1.5 mm2
Module operation
Module configuration Module configuration The module is operated, set and diagnosed from the Mosaic development environment.
Commissioning The module is operated, set and diagnosed from the MOSAIC programming environment or other parameterization software. The module is ready for operation after connecting the supply voltage and the CIB bus. The HW address is listed on the label on the module.
Module diagnostics Basic diagnostics are performed internally and the result is available in the relevant registers of the Mosaic environment.
Maintenance
Description The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected.
Notice Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!!
Warranty
Generally Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
Notice You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.

User manuals

PDF

Peripheral module on CIB-Common Installation Bus(R) (cs), TXV00413_01

13.82 MB
PDF

Peripheral modules on the CIB Common Installation Bus(R) (en), TXV00413_02

13.94 MB, (EN, RU, DE, UA)

HW documentation

PDF

C-IT-0500I - Basic documentation

275.43 kB, (EN)

Files for designers

ZIP

Foxtrot 2 - library of elements in DXF and DWG formats, v. 2025/08.

21.80 MB
KNI

Foxtrot 2 - element library for SchemataCAD, v. 2025/08.

6.96 MB

EC - Declaration of Conformity

PDF

Foxtrot 2 - EC Declaration of conformity (en)

590.59 kB, (EN, RU, DE, UA)

No data available.