C-RS-0200R-LOGUS, ivory, TMFTXN 133 79.LTMF
C-RS-0200R-LOGUS ivory; CIB, device rotary knob + button, temperature sensor, 2x AI
DI | 2x AI/DI 1x Button |
---|---|
DO | |
AI | 2x AI / DI see DI |
AO | |
COM | 1x CIB slave |
SENSOR | Rotary bidirectional incremental encoder |
Picture | Variant | Variant description |
---|---|---|
C-RS-0200R-LOGUS - white | Color: White | |
C-RS-0200R-LOGUS, ivory, TMF | Color: Ivory | |
C-RS-0200R-LOGUS, ice, TGE | Color: Ice | |
C-RS-0200R-LOGUS, Pearl, TPE | Color: Pearl | |
C-RS-0200R-LOGUS, aluminum, TAL | Color: Aluminum | |
C-RS-0200R-LOGUS, gray, TIS | Color: Grey | |
C-RS-0200R-LOGUS black | Color: Black | |
C-RS-0200R-LOGUS gold | Color: Gold |
C-RS-0200R is a rotary knob with the function of a confirmation button with connection to the CIB Common Installation Bus®, to which 2 external temperature sensors or 2 contacts can be connected.
Order num. | TXN 133 79.LTMF |
---|---|
Teco code | TXN 133 79.LTMF |
Categories | CFox - LOGUS, Covers and devices |
Tags | - |
COM - System buses | |
---|---|
CIB - Common Installation Bus (R): Installation I/O bus | 1x CIB slave |
DI - Parameters of binary inputs DC (group A) | |
Number of inputs in group | 2 |
Common wire | GND - module ground |
Combined input type | DI/AI Active, for sensing potential-free contacts and measuring resistance sensors |
AI - Analog Input Ranges (Group A) | |
Parameters valid for inputs on the terminals | AI0/DI0, AI1/DI1 |
Voltage | 0-2 V |
Passive sensor | Pt1000, W100 = 1,385 (-90 to +400 ° C) |
Passive sensor | Pt1000, W100 = 1,391 (-90 to +400 ° C) |
Passive sensor | Ni1000, W100 = 1,500 (–60 to +200 ° C) |
Passive sensor | Ni1000, W100 = 1.617 (-60 to +200 ° C) |
Passive sensor | Resistance transmitter 0-100 kOhm |
Passive sensor | KTY81-121; PTC thermistor (-55 to + 125 °C) |
Passive sensor | NTC Thermistor 12k / 25 °C (-40 to + 125 °C) |
DI: Voltage-free contact | 0 when> 1.5 kOhm, 1 when <0.5 kOhm |
Power supply | |
Supply voltage, tolerances | 24/27 V DC from CIB bus |
Power supply from CIB - voltage | 24/27 V DC |
Typical power input | 0,2 W |
Maximum power input | 0,3 W |
Power supply from CIB - typical current consumption (mA) | 8 mA |
Power supply from CIB - maximum current consumption (mA) | 13 mA |
Power supply from CIB - internal protection | No |
Size and weight | |
Weight approx. | 75 g |
Product dimensions (width x height x depth) | 70 × 70 × 25 mm |
Operating conditions, product standards | |
Product standard | ČSN EN 60730-1 ed.4 :2017 (EN 60730-1:2016) -Automatic electronic control device (for household and similar purposes) |
Protection class of electrical object | II, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016) |
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) | IP40 front, IP20 rear |
Operating areas | Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005) |
Degree of pollution | 1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007) |
Type of device | In the installation box on the wall |
Working position | Vertical |
Type of operation (operating frequency) | Continuous |
Ambient operating temperatures | -10 °C to + 55 °C |
Operating temperature maximum (° C) | +55°C |
Operating temperature minimum (° C) | -10°C |
Operating relative humidity | from 10 % up to 95 % without condensation |
Operating atmospheric pressure | min. 70 kPa (<3,000 m above sea level) |
Storage temperatures | –25 °C to +70 °C |
Electromagnetic compatibility, Mechanical endurance | |
Electromagnetic compatibility / Emission | A, according to EN 55032 ed. 2: 2017 (idt CISPR 32: 2015) |
Electromagnetic compatibility / Immunity | min. according to ČSN EN 60730-1 ed.3: 2012 |
Sinusoidal vibration endurance | 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.) |
Installation | |
Assembly description |
The module is mounted in a vertical position on a standard installation box with a spacing of fixing screws of 60 mm. Method:
|
Connection | |
Connection description | The controller module with rotary control with the possibility of connecting external sensors is implemented as a standard unit on a two-wire CIB bus, which ensures communication and power supply of the entire module. The CIB bus can have any topology and branching up to a distance of 500 m and up to 32 units on one CIB branch. The CIB bus master is the FOXTROT basic unit with the internal module CF-1140 or the external module CF-1141, with version FW 1.8 and higher. Further information can be found in the manual “Peripheral modules on the CIB bus” TXV 004 13. |
Connection of power and system communication | Loose wires in the connector / 0.15-0.5 mm2 |
Connection of inputs / outputs | Loose wires in the connector / 0.15-0.5 mm2 |
Cross-section of connected wires fixed (max) | 0,5 mm2 |
Module operation | |
Module configuration | SW configuration, operation and diagnostics of the C-RS-0200R-ABB module are performed from the MOSAIC programming environment. The module is ready for operation after connecting the CIB supply voltage. The HW address of the respective module is indicated on the type plate on the board. |
Module diagnostics | The basic diagnostics is performed internally and the result is available in the relevant registers of the Mosaic environment. |
Maintenance | |
Description | The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected. |
Notice | Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!! |
Warranty | |
Generally | Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s. |
Notice | You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change. |
HW documentation
C-RS-0200R - Basic documentation
128.96 kB
User manuals
Peripheral modules on the CIB Common Installation Bus(R) (en), TXV00413_02
13.94 MB, (EN, RU, DE, UA)
Files for designers
Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.
20.49 MB
Foxtrot 2 - element library for SchemataCAD, v. 2024/01
6.79 MB
EC - Declaration of Conformity
Foxtrot - EC Declaration of conformity
295.20 kB, (EN, RU, DE, UA)
- C-RS-0200R - ...00-270xx (Variant and Elegant). The frame in the selected design and colour. The body proper of the C-RS-0200R-Logus or C-RS-0200R-Obzor module. Mounting of the module: Screw the C-RS-0200R-Logus...
- A rotary controller on the CIB, the C-RS-0200R - The C-RS-0200R-Logus is a rotary interior controller with the function of one button with a connection to the CIB. At the same time it is fitted with two universal inputs terminated in the terminal block on the rear side of the module, e.g. f...