R-SL-0201L-A, relay module and PWMTXN 132 43.A
R-SL-0201L-A; RFox2, 2x AI/DI, 1x RO-800A NO contact, radio type A
DI | 2x AI/DI |
---|---|
DO | 1x RO 1x PWM |
AI | 2x AI / DI, see DI |
AO | |
COM | 1x RFox2 slave |
SENSOR | Current |
Picture | Variant | Variant description |
---|---|---|
R-SL-0201L-A, relay module and PWM |
R-SL-0201L is a module designed for remote control of a street lamp in the RF network of the RFox II system. The module contains 1x relay output for switching the power source of the lamp, PWM output for brightness control, lamp internal current measurement and 2x AI/DI input. The module can be used for switching general loads, see parameters in the documentation.
Order num. | TXN 132 43.A |
---|---|
Teco code | TXN 132 43.A |
Categories | RFox2 - DIN Rail Modules |
Tags | - |
COM - Wireless network | |
---|---|
RFox2 wireless network | RFox2 Slave |
Communication frequency band | 868,1 MHz |
Transmission power | +14 dBm |
Input sensitivity | –108 dBm |
Modulation type | 2-GFSK |
Communication speed | 50 kbps |
Transmission frequency | 868,1 MHz |
Number of channels | 1 |
DI - Parameters of binary inputs DC (group A) | |
Parameters valid for inputs on the terminals | AI/DI1, AI/DI2 |
Number of inputs in group | 2 |
Common wire | minus |
Combined input type | DI/AI Active, for sensing potential-free contacts and measuring resistance sensors |
Galvanic isolation of inputs from internal/peripheral circuits | No |
Diagnostics | signaling of excited input in Mosaic |
Max. measuring voltage on the connected contact | 3,3 V DC |
Internal input resistance | 4,7 kΩ |
RO - Parameters of binary relay outputs (group A) | |
Parameters valid for the terminals | DO1, COM |
Number of relay outputs | 1 |
Output type | electromechanical relay, unprotected output |
Contact type | NO - Normally Open |
Switching current | 12 A max., 100 mA min. |
Switching voltage | 250 V AC max., 5 V AC min., 30V DC max. |
Switching power | 250 W (with current measuring), 2760 W (without current measuring), see connection diagrams |
Short-term output overload - inrush | max. 800 A (max. 200 μs) |
Contact opening time | typ. 4 ms |
Limit values of switched resistive load | max. 3A at 30 V DC or 230 V AC |
Switching inductive load limits DC13 | max. 3 A at 30 V DC |
Switching inductive load limits AC15 | max. 3 A at 230 V AC |
Switching frequency without load | max. 300 switching / min. |
Mechanical life | min. 5,000,000 cycles |
Electrical life at maximum resistive load | min. 100,000 cycles |
Electrical life at maximum load inductive DC13 | min. 100,000 cycles |
Electrical life at maximum load inductive AC15 | min. 100,000 cycles |
Short-circuit protection | No |
Treatment of inductive load | External RC element, varistor (AC), diode (DC) |
AI - Analog Input Ranges (Group A) | |
Parameters valid for inputs on the terminals | AI/DI1, AI/DI2, N |
Voltage | 0-3,3 V |
Passive sensor | Resistance transmitter 0-15 kOhm |
Passive sensor | NTC Thermistor 12k / 25 °C (-40 to + 125 °C) |
DI: Voltage-free contact | 0 when> 1.5 kOhm, 1 when <0.5 kOhm |
Power supply | |
Nominal supply voltage (V) | 230 V AC |
Typical power input | 3 W |
Maximum power input | 4,5 W |
Maximum current consumption (mA) | < 20 mA |
Galvanic separation of power supply from internal circuits | No |
Internal protection | No |
Size and weight | |
Weight approx. | 50 g |
Product dimensions (width x height x depth) | 35 x 92 x 40 mm |
Module width | 35 mm |
Module height | 92 mm |
Module depth | 40 mm |
Operating conditions, product standards | |
Product standard | ČSN EN 61131-2:2008 (idt IEC 61131-2:2007) - Programmable control units |
Protection class of electrical object | II, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016) |
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) | IP20 |
Operating areas | Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005) |
Degree of pollution | 1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007) |
Overvoltage category installation | I, according to ČSN EN 60664-1 ed_2:2008 (idt IEC 60641-1:2007) |
Type of device | Module on DIN rail |
Working position | Any |
Type of operation (operating frequency) | Continuous |
Ambient operating temperatures | -20 °C to + 55 °C |
Operating temperature maximum (° C) | +55°C |
Operating temperature minimum (° C) | -20°C |
Operating relative humidity | from 10 % up to 95 % without condensation |
Operating atmospheric pressure | min. 70 kPa (<3,000 m above sea level) |
Storage temperatures | –25 °C to +70 °C |
Electromagnetic compatibility, Mechanical endurance | |
Electromagnetic compatibility / Emission | A, according to EN 55032 ed. 2: 2017 (idt CISPR 32: 2015) |
Electromagnetic compatibility / Immunity | min. as required by EN 61131-2: 2007 |
Sinusoidal vibration endurance | 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.) |
Packaginng, transportation, storage | |
Description | The module is packed in a paper box. This documentation is also part of the package. The outer packaging is carried out according to the scope of the order and the method of transport in a transport package provided with labels and other data necessary for transport. The product must not be exposed to direct weather conditions during transport and storage. Malting of the product is only allowed in clean rooms without conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C |
Installation | |
Assembly description | Mounting in a cabinet or luminaire |
Attention! | The device may contain parts with dangerous voltages, covers being removed, or cabling manipulated, or disconnect the appropriate circuits or turn off the power !. |
Connection | |
Power connection | terminal block with spring terminal 1.5 mm2, push-in |
Connection of inputs / outputs | terminal block with spring terminal 1.5 mm2, push-in |
Wireless network - antenna | Wireless network - antenna SMA connector (male) |
Module operation | |
Module configuration | The module is operated, set up and diagnosed from the Mosaic development environment. |
Commissioning | The module is operated in the RFox2 radio network as a peripheral module, the settings are made in the Mosaic programming environment project manager, see the TXV 003 93 manual with the description of RFox2Lib. |
Module diagnostics | The basic diagnostics is performed internally and the result is available in the relevant registers of the Mosaic environment. |
Maintenance | |
Description | The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected. |
Instructions | Because the module contains semiconductor components, it is necessary to follow the principles for working with components sensitive to electrostatic charges during handling. Repairs are performed exclusively by the manufacturer's service center or the manufacturer's authorized service. |
Warranty | |
Generally | Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s. |
Notice | You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change. |
HW documentation
R-SL-0201L-A Basic Documentation
1.26 MB, (EN)
Files for designers
Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.
20.49 MB
Foxtrot 2 - element library for SchemataCAD, v. 2024/01
6.79 MB
- Example of DLC-Prog 70W driver control by R-SL-0201L-A VO lamp module - The connection example shows the ballast control for the LED source by the R-SL-0201L-A module. The ballast used in the example is Layrton DLC-prog 70W . It is a programmable very universal ballast, which allows control of the brightness o...
- Example of GPF-60D-1400 driver control by R-SL-0201L-A VO lamp module - Fig. 1 shows an example of connection of the R-SL-0201L-A module for brightness control of the GPF-60D-1400 LED driver, eg for installation in a VO lamp. Fig. 1 example of lamp driver control by a R-SL-0201L-A module No...
- R-SL-0201L-A - R-SL-0201L is a peripheral module designed, for example, for remote control of a street lamp in the RF network of the RFox2 system. The module contains 1x relay output for switching the lamp power supply, PWM output for brightness control, intern...
- Smart City - modules for controlled control of ballasts for public lighting - ...dnoho až dvou předřadníků pro použití v lampách veřejného osvětlení. C-DM-0002L-10V is two-channel on CIB buses, The R-SL-0201L-A is single-channel connected to the Foxtrot control panel wirelessly at a frequency of 868MHz. It has two inputs...
No data available.