R-DL-0203L-A, control 3x DALITXN 142 22.A

R-DL-0203L-A; RFox2, 2x AI / DI, 3x DALI (broadcast), type A radio

DI 2 AI/DI
DO 3x PWM (alternation of DALI outputs)
AI 2 AI / DI see DI
AO
COM
SENSOR
Picture Variant Variant description
R-DL-0203L-A, control 3x DALI
R-DL-0203L-A; RFox2, 2x AI / DI, 3x DALI (broadcast), type A radio
Order num. TXN 142 22.A
Teco code TXN 142 22.A
Categories RFox2 - DIN Rail Modules
Tags -
COM - Serial channels
Communication interface DALI 3x DALI master
The scope of each DALI line 4 addresses / substations
COM - Wireless network
RFox2 wireless network RFox2 Slave
Communication frequency band 868,1 MHz
Transmission power +14 dBm
Input sensitivity –108 dBm
Modulation type 2-GFSK
Communication speed 50 kbps
DI - Parameters of binary inputs DC (group A)
Parameters valid for inputs on the terminals AI/DI1, AI/DI2
Number of inputs in group 2
Common wire minus
Combined input type DI/AI Active, for sensing potential-free contacts and measuring resistance sensors
Galvanic isolation of inputs from internal/peripheral circuits No
Input current at log. 1 (typ.) 0,5 mA typ.
DO - Parameters of binary transistor outputs (group A)
Parameters valid for the terminals DA-. DA1+, DA2+ DA3+, (A2, A3, A4, A5)
Number of transistor outputs 3
Number of output groups 1
Number of outputs in group 3
Common group conductor minus
Output type Low-side
Galvanic separation from internal circuits No
Resting output level 24 V DC + -5%
Switching current, output load 100 mA max.
Special functions (A) PWM
Special function (B) DALI, bidirectional master
Operating frequency 1 Hz - 1 kHz
Alternation settings 0 – 100 %
Power supply
Supply voltage, tolerances 90 – 270 V AC
Input voltage frequency 50-60 Hz
Maximum power input 2 W
Galvanic separation of power supply from internal circuits No
Insulation voltage of galvanic separation 3 000 VDC
Internal protection Yes, non-refundable
Size and weight
Weight approx. 75 g
Product dimensions (width x height x depth) 35 × 92 × 40 mm
Operating conditions, product standards
Product standard ČSN EN 60730-1 ed.4 :2017 (EN 60730-1:2016) -Automatic electronic control device (for household and similar purposes)
Protection class of electrical object II, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) IP20
Operating areas Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution 1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007)
Overvoltage category installation II, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of device Module on DIN rail
Working position Any
Type of operation (operating frequency) Continuous
Ambient operating temperatures -20 °C to + 55 °C
Operating relative humidity from 10 % up to 95 % without condensation
Operating atmospheric pressure min. 70 kPa (<3,000 m above sea level)
Storage temperatures –25 °C to +70 °C
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / Emission B, according to EN 55032 ed. 2: 2017 (idt CISPR 32: 2015)
Electromagnetic compatibility / Immunity min. according to ČSN EN 60730-1 ed.3: 2012
Sinusoidal vibration endurance 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.)
Packaginng, transportation, storage
Description The module is packed in a paper box. This documentation is also part of the package. The outer packaging is carried out according to the scope of the order and the method of transport in a transport package provided with labels and other data necessary for transport. The product must not be exposed to direct weather conditions during transport and storage. Malting of the product is only allowed in clean rooms without conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C
Connection
Connection description An example of module connection is shown in the following figure. Any type designed for the 868 MHz band with an SMA connector (pin) can be used as an antenna.
Warnings / Cautions CAUTION: The device contains parts with dangerous voltage, disconnect the relevant circuits or switch off the power supply before removing the covers or handling the wiring!
Module operation
Commissioning The module is operated in the RFox2 radio network as a peripheral module, the settings are made in the Mosaic programming environment project manager, see the TXV 003 93 manual with the description of RFox2Lib.
Module diagnostics The basic diagnostics is performed internally and the result is available in the relevant registers of the Mosaic environment.
Maintenance
Description The module does not require any maintenance under general installation conditions.
Warning Because the module contains semiconductor components, it is necessary to follow the principles for working with components sensitive to electrostatic charges during handling. Repairs are performed exclusively by the manufacturer's service center or the manufacturer's authorized service.
Warranty
Generally Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
Notice You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.

HW documentation

PDF

R-DL-0203L-A - Basic documentation

173.13 kB

Files for designers

ZIP

Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.

20.49 MB
KNI

Foxtrot 2 - element library for SchemataCAD, v. 2024/01