RF-2131-ATXN 121 31.A
RF-2131-A; Single-channel external master of the RFox2 network, on the TCL2 system bus
DI | |
---|---|
DO | |
AI | |
AO | |
COM | 1x TCL2 slave 1x RFox2 master |
SENSOR |
Picture | Variant | Variant description |
---|---|---|
RF-2131-A |
The RF-2131-A module is a system communication module enabling the connection of RFox2 wireless network modules or mutual wireless communication between several PLCs.
The module is operated by the RFoxMaster library in the Mosaic development environment.
TECOMAT FOXTROT central units allow the connection of up to 8 RF-2131-A system communication modules.
The module is operated by the RFoxMaster library in the Mosaic development environment.
TECOMAT FOXTROT central units allow the connection of up to 8 RF-2131-A system communication modules.
Order num. | TXN 121 31.A |
---|---|
Teco code | TXN 121 31.A |
Categories | RFox2 - System Modules, Foxtrot - Communication Modules (TCL2) |
Tags | - |
COM - System buses | |
---|---|
TCL2 - system I/O bus | 1x TCL2 slave |
The communication rate of the system I / O bus | 345 kbps |
COM - Wireless network | |
RFox2 wireless network | RFox2 Master |
RFox2 wireless network range | up to 256 RFox2 slave nodes |
Communication frequency band | 868,1 MHz |
Transmission power | +14 dBm |
Input sensitivity | –108 dBm |
Modulation type | 2-GFSK |
Communication speed | 50 kbps |
Transmission frequency | 868,1 MHz |
Power supply | |
Supply voltage, tolerances | 24 V DC, +25%, -15%, SELV |
Maximum power input | < 0,5 W |
Module thermal/power loss | 0,4 W |
Internal protection | Yes |
Size and weight | |
Weight approx. | 75 g |
Product dimensions (width x height x depth) | 18 x 90 x 58 mm |
Module width in multiples of M (17.5 mm) | 1M |
Operating conditions, product standards | |
Product standard | ČSN EN 60730-1 ed. 2:2001 (mod IEC 60730-1:1999) |
Protection class of electrical object | III, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016) |
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) | IP10B |
Operating areas | Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005) |
Degree of pollution | 1, according to ČSN EN 60664-1: 2004 (mod IEC 60664-1: 1992) |
Type of device | Module on DIN rail |
Working position | According to the installation description |
Type of operation (operating frequency) | Continuous |
Ambient operating temperatures | -20 °C to + 55 °C |
Operating relative humidity | from 10 % up to 95 % without condensation |
Operating atmospheric pressure | min. 70 kPa (<3,000 m above sea level) |
Storage temperatures | –25 ° C to + 85 ° C |
Electromagnetic compatibility, Mechanical endurance | |
Electromagnetic compatibility / Emission | B, according to EN 55032 ed. 2: 2017 (idt CISPR 32: 2015) |
Electromagnetic compatibility / Immunity | min. according to ČSN EN 60730-1 ed.2: 2001 |
Sinusoidal vibration endurance | 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.) |
Connection | |
Connection description |
An example of module connection is shown in the following figure. If the module is connected at the end of the TCL2 line, the terminator KB-0290 must be used. The module address on the TCL2 bus is set with the rotary switch. Any type designed for the 868 MHz band with an SMA connector (pin) can be used as an antenna. |
Connection description | An example of module connection is shown in the following figure. |
Module operation | |
Module diagnostics | The basic diagnostics is performed internally and the result is available in the relevant Mosaic environment registers |
Maintenance | |
Description | The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected. |
Notice | Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!! |
Warranty | |
Generally | Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s. |
Notice | You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change. |
HW documentation
RF-2131 - Basic documentation (en)
5.60 MB, (EN)
Files for designers
Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.
20.49 MB
Foxtrot 2 - element library for SchemataCAD, v. 2024/01
6.79 MB
EC - Declaration of Conformity
Foxtrot 2 - EC Declaration of conformity (en)
590.59 kB, (EN, RU, DE, UA)
No data available.
No data available.