DSDS

DS, Hochwassermelder, leitend, IP65

DI
DO
AI
AO
COM
SENSOR
Bild Produktvarianten Variantenbeschreibung
DS
DS, Hochwassermelder, leitend, IP65
Bestellnummer 8020102817
Teco-Code DS
Kategorien Niveau, Überschwemmung
Stichworte -

Keine Daten verfügbar.

  • CF-2141 CIB master for Foxtrot 2_kopie335 - ...A, ie the total consumption at the maximum load of the CIB output is 1.1 A. There are 2 indicator LEDs on the front panel: PWR indicates the power supply of the CF-2141 module CIB indicates communication...
  • Example of DLC-Prog 70W driver control by R-SL-0201L-A VO lamp module - ...st. The table shows that the power of the luminaire can be regulated from approx. 24 W to 80 W of electrical input (corresponds to the PWM output range of the module 10% to 100%). For this converter it is necessary to connect a series resistor of...
  • Foxtrot 2 with WiFi interface - ...on. CONNECT IT CI-232 Mini Adapter 150Mb/s: Frequency: 2.4 GHz Interface: USB 2.0 Baud rate: 150 Mbps Standards: 802.11 b/g/n Antenna: internal Range of: 10m     Small WiFi module TP-LINK...
  • Function block fbEVSEChargerAC and its use with C-EV-0302M - ...harge and Lock . output is closed. This starts charging the electric car. When the vehicle is fully charged, it adds to the interruption of charging and disconnection of the contactor. In Manual mode, after connecting the vehicle,...
  • Connecting multiple CF-2141s to a single CP-2005 - ...o one Foxtrot 2 basic module using the SX-1161 Ethernet switch . The example does not show the power connection. It depends on the location of individual CF-2141 (when placed in different cabinets, it is always necessary to use the power supply...
  • CF-2141 CIB master for Foxtrot 2 - ...A, ie the total consumption at the maximum load of the CIB output is 1.1 A. There are 2 indicator LEDs on the front panel: PWR indicates the power supply of the CF-2141 module CIB indicates communication...
  • Example of RFox2 module operation R-IT-0500S - ...4 and a common COM are reserved for 4 digital inputs on the module. When a COM is connected to one of the DIs, the module sends a DI activation packet (log. 1). Processing and sending time is around 180 ms. Sending a log. 1 is repeated for the period...
  • R-IT-0500S - ...ation lasts longer than 400 ms, the packet transmission module repeats a total of one hundred times. Then the transmission ends even if the input is still energized. After transmission, the module switches to the reduced consumption mode, and if the...
  • Control of Yeelight lights using the Foxtrot system - ...vation set on his wifi router in the DHCP server configuration for the MAC address of the given lighting device. In other words, the light must always obtain the same IP address from the DHCP server after logging in to the network. The MAC address of...
  • C-EM-0300M (R-EM-0300M-A) - measurement of production and consumption of el. energy, 3f fast - ...is designed for installation on a DIN rail. It is suitable for a wide range of applications in energy and so-called smart grids, in the automation of buildings and individual production processes, for remote monitoring of infrastructure and also for...
  • Openable transformer for current measurement with 333 mV output - .... Demonstration of the correct orientation of the transformer on the conductor in the direction from the supply (POWER) towards the load (LOAD)   Fig. 3. Transformer output characteristics including permissible overload...
  • C-OS-0808M - ...t pulse width modulation (PWM) on the outputs. The states of the individual inputs / outputs are indicated by indication LEDs.  The individual outputs allow local manual control by buttons on the module.   ...
  • C-WG-0205S and SL031 reader connection example and EV-T2SOC-P socket LED indication - ...dule contains 2 universal DI/AI inputs and 5 DO/PWM outputs. The module enables powering, for example, of the indicator LEDs of the charging socket, it is equipped with a 22 VDC output with a maximum load of 60 mA (terminal A3). The module is e...
  • Web Push Notifications - sending notifications from the Foxtrot system - ...ndow. The only necessary condition for subscribing to notifications is an installed Internet browser, with which the user loads the web pages of the server and registers the subscription. This service, intended primarily for web servers, was also...
  • C-DM-0002S-SL - The C-DM-0002S-SL module is intended for the control of addressable RGB LEDs (type WS2812B and compatible), which can be used either directly in the form of a classic strip or various sets of these LEDs (mechanical arrangement in a matrix, circle, e...
  • C-AQ-0006R - ...ng operation, no further calibration is required. The iVOC sensor is an advanced sensor sensitive to volatile organic compounds typically contained in exhaled air, gaseous metabolic products of the human body and other gaseous pollutants such as form...
  • C-AQ-0005R - ...-10 ÷ +60 °C  Accuracy ±2 °C Thresholds 1) -10 °C, +55 °C Power supply Power and communication...
  • operation C-DM-0002S-SL - The C-DM-0002S-SL module is intended for the control of addressable LEDs, which can be used either directly in the form of a classic strip or various assemblies of these LEDs (mechanical arrangement in a matrix, etc.). In total, one module can...
  • operation C-RC-0006R - C-RC-0006R is a room wall controller with capacitive buttons designed to control lights, scenes, blinds, heating and audio. It allows measurement of temperature, humidity and lighting intensity in the room, connection of 2 universal AI / DI inputs....
  • MR-0105, MR-0106, MR-0115, fitted with the CP-10x6, CP-10x8 - ...MR-0106 MR-0115 D1 GNDS GNDS GNDS D2 TxD4...
  • MR-0105, MR-0106, MR-0115, fitted with CP-1000, CP-1001, CP-1003, CP-1091 - ...- - - D2 GNDS GNDS GNDS D3 TxD4...
  • MR-0105, MR-0106, MR-0115, fitted with the CP-10x4, CP-10x5 - ...- - - C2 GNDS GNDS GNDS C3 TxD4...
  • FVE, HFVE basic components - ...in accurate orientation to the sun and direct light, while polycrystalline panels work better in poorer orientation and clouds, so for common stationary applications on the roof of the house there is not much difference between them.   Ex...
  • Foxtrot 2 with LTE modem - ...sending SMS messages is handled by a function block from GSMLib. A nano SIM card can be installed. We supply TELE2 SIM cards, the advantage of which is that they are not tied to a specific operator, the supplier of these SIMs has concluded roaming...
  • Antennas for RFox2 in version A, 868 MHz - ...or for connecting an external antenna (eg modules C-RF-0001M-A , R-EM-0300M-A and others). Standards ZigBee, ISM, SIGFOX, LoRa Frequency band (MHz) 868 MHz Fre...
  • WiFi antennas - ...uitable for WiFi modules equipped with an SMA connector for connecting an external antenna . Standards BT, WIFI Frequency 2.4GHz, 5.0GHz, 5.1-5.9GHz Max. Gain...
  • Binary output module OS-8410 - The OS-8410 module is designed to control up to 32 loads of 24 V DC / 0.05 A - especially external modules on the DIN rail series OS-04xx or OR-04xx. The outputs are realized by semiconductor switches. The module is equipped with two connectors, t...
  • Examples of power connections for TC800 modules - ...of peripheral modules, including OS-8401. The ZD3 power supply is only for powering the module's switched module loads, max current 8A common terminal VDO+ (A1). 1) For the correct operation of the output power swit...
  • C-WS-0001R - ...module configuration, as well as the sound response to the press. The buttons are illuminated either collectively by white LEDs, or separately by point LEDs for each button separately (red and green). Fig. 2 Buttons with flat white backlight...
  • Recommendations for placement of indoor air quality sensors - ...Unsuitable conditions Near the windows Near the front door On external (perimeter) walls (depends on wall insulation - surface temperature of external walls) In places with limited air circulation such as vestibules...
  • How to choose the right type of indoor air quality sensor - ...vity. In such a space, the concentration of CO2 can be at a relatively good level, but the air feels clearly polluted and needs to be ventilated. In the above-mentioned spaces, another source of pollution can therefore prevail over the stand...
  • Indoor air quality and how the terms VOC, TVOC and CO2 relate to it - Concept"VOC"  or volatile organic substances arose from the English Volatile Organic Compounds. (Volatile = volatile, i.e. at room temperature in a gaseous state).  People became more interested in air quality only in the...
  • Communication interface submodule connector on the CP-8001 module - ...tain serial channels of RS-232 or RS-485  interface.   For the proper functioning of the RS-485 it needs to be terminated at both ends. We perform it on the submodule by soldering the solder jumper marked BT1 (first channel) or...
  • Example of calculating the capacity of the backup battery for the CP-2005 power supply - ...dule. The typical power consumption of the CP-2005 basic module, with the relays open, is approx. 3W (each closed relay adds approx. 0.2W). The quiescent power of the LTE part of the CP is approx. 0.1 W, the peak maximum power during transmissi...
  • Central module CP-8001 - ...ger variables to an absolute address in the PLC memory. Indication elements and setting options   Indication LEDs The central modules contain RUN and ERR LEDs, which indicate the central unit mode (see tab.2.11). LED1 indicates th...
  • Power supply modules PW-8901 and PW-8902 - ...ting the TCL3 bus on PW-8901 modules for a PLC assembly with three frames Notes: The TCL3 bus corresponds in its characteristics to the RS-485 interface at a speed of 3 Mbd, i.e. suitable shielded cables for this interface and c...
  • TC800 CENTRAL MODULES - ....2    Example of an assembly with two TCL2 buses Notes: This bus uses metal cables to connect, corresponds to the RS-485 interface and must be terminated at both ends. Submodules SE-0140 contain the end of the bus and must always...
  • Wireless heating switching, lighting by R-IS-0203M module - The R-IS-0203M module can be used for wireless control of various loads, these outputs are switched by power relays. Fig. 1 shows the switching of 3 relays RT (Schrack) directly by outputs PWM1 to PWM3, which are used as normal binary outputs (from...
  • SYSTEM BUS AND MECHANICAL DESIGN OF TC800 MODULES - ...nnectors and is available in five dimensional variants. It is inserted into the DIN rail and secured with brackets at both ends of the bus. The individual modules can then be mounted on the bus anywhere, except in the bus holder area. The modules are...
  • TECOMAT TC800 SYSTEM FEATURES - ...placing the previous TECOMAT TC700 series). It is a modular system with the possibility of construction according to user needs. The TECOMAT TC800 central units are similar in their characteristics to the central units of the TECOMAT FOXTROT 2 compac...
  • Residual current submodule S-EV-0001X-RC for module C-EV-0505M - application note - ...gnaled simultaneously in the module status variables. The fault condition is simultaneously signaled by the red indicator LEDs on the front panel of the C-EC-0505M module. The module remains in this state until the user intervention, which is realiz...
  • Foxtrot 2 series PLC in the role of Modbus TCP slave station compatible with Foxtrot 1 - ...amely the fbModbusTCPslave function block. In most cases, this block is used in such a way that it reserves user-defined fields for Modbus TCP access and the rest of the scratchpad is protected against access by this protocol. In case the backward...
  • Save and load values of {PUBLIC} variables from / to file - ...sembler file (.pub)) must be checked. "). The fbSavePubVar() function block selects variable names from a .pub file, reads their current value using the GetVarValueByName () function, and then saves the variable name and value to a file on the S...
  • Online switchboard design - BONEGA application - ...obtain a production label with a QR code including the relevant documentation, which always complies with the latest standards. Allows you to combine devices and switchboards cabinets from different manufacturers. The application automatically ca...
  • How to create a library in the Mosaic environment - ...s path can be changed by the user (see Project Manager / Common Settings / Folder Settings). The generation of the library ends with the display of a message, from which the result is evident and on which libraries the newly created library depends a...
  • Communication server PLCComS - ...th clients is solved using a simple text-oriented protocol REQUEST/ANSWER. Therefore, the client queries the server by commands for the values of variables whose names are symbolic and are described in public file. However, it is possible to use dire...
  • PV Forecast - weather forecast for FVE, HFVE management - ...precipitation total for 48 hours in an hourly interval. The forecast is updated before 12 noon and noon, and from noon onwards the forecast for the next day is available, which is further specified by the forecast issued before midnight.  ...
  • People counting and averaged temperature map with C-IF-6400R Grid-Eye sensor - ...SamplingTimer : TON; people_counter_fb : fbPeopleCounter; END_VAR // The GridEye function block needs the whole DATA structure from the sensor C-IF-6400R passed to the input sensor_data // The function block has three outpu...
  • Two-point controlled VZK zone ball valve - ...he zone valves are further divided in accordance with their use, maximum and closing pressure, temperatures and types of fluids, types of electrical drives and security features. The zone valves are usually designed with a two-point control, allow...
  • The three-point controlled DANFOSS AMV 20 drive - An example of a three-point controlled regulation valve is shown in the following figures. The example uses a three-point controlled DANFOSS AMV 20, a drive with the 230 VAC supply voltage, power consumption 2 VA. The actuator is controlled b...
  • CP-2xxx factory defaults - ...er an unsuccessful atempt to update the PLC certificates the management portal is not accessible anymore.   Best regards, Romel...
  • CP-2000 error - ...5.988877  Error E-92-40-01C200 Runtime error: Invalid pointer Can I find the source of the error somewhere? best regards: Balázs...
  • Taian TW-10 PLC - ...An Electric Co., Ltd in 2003 What connecting cable and software would we need? Any information would be appreciated. Regards Aaron Brisbane, Australia...
  • Google Home inetgration - ...t on PLC. I found fbModbusTCPslave, but I'm not sure if this is my way. Are there any examples about the usage of it? Regards, Zsolt    ...
  • Analog input - ...input 0-10V? Can I use AI of C-IR-0303M with input 0-10V? In case it is not possible which module  I could buy? Regards  ...
  • TCIB_CRC011R_ICO Structure - ...ucture on the device but I didn't find the TCIB_CRC011R_ICO structure in the libraries. I made a structure with the same fields but it doesn't work. Could you send me a library which contains the correct structre? Thanks in advance! Arpi...
  • DMX with MR-0114 submodule - Hi, Is it possible to use DMX512 with MR-0114 submodule?  Regards, Zsolt
  • HW configurator in Mosaic 2021 - ...it should be on same place as early mosaic, in project folder, hw. But I did not see it there. Any suggestion please? Regards, Zsolt...
  • Technical documentation - ...nical documentation regarding the basic module CP-1006, manual/design guide/other. Thank you in advance.   Kind regards, Ana Pinto...
  • iFoxtrot App to control PLC - ...set PLS variables remotely, if mobile phone is on internet? Port forwarding port 5010 on routeris enough?   Regards, Zsolt Kantor...
  • Modbus TCP on Foxtrot CP-2xxx units - ...ze: 260; Protocol: TCP server   //Variables ModbusTCPLine : fbModbusTCPmas2; ModbusTCPCommand : ARRAY [0..30] OF TCmdStructTCP; ModbusTCPGroup : USINT; UINTArray : ARRAY [1..20] OF UINT;   //Modbus initialization with a fbModbusTCPm...
  • Single user web interface for several Foxtrots - ...ers as the "main" one and achieve duplication of all web pages from all controllers onto this "main" controller. In other words, they want to have a single unified user web interface on the "main" controller that includes all web pages from all four...
  • iFoxtrott iDisplay_OnOff Icon issue - ...into PLC WWW / iFOX / directory with no success. Is there a resolution or color restriction? Can you help me please? Regards, Zsolt Kántor  ...
  • Advent first sunday - Hello! Is there a built-in function in mosaic that calculates the date of the first Sunday of Advent? Regards, Balázs Marozs
  • fancoil Isan/Zehnder . How to conect CIB and KNX ? - ...e connector between CIB and KNX-system or something else (I think about new thermostat or new panel too) ?   Regards Przemek Piechota...
  • Apple Homekit blind positioning - Hello! I have run into the following issue: a client wants to control their blinds via Apple Homekit, so the controlling blocks were made via fb_iJalousie. They can start the blinds with pressing the opening or closing button, but when they issue a...
  • Examples - where I can find some simple programming examples in IL and ST languages? Could you send me? Regards    
  • Mosaic 2020.1 SP3 - [ST:Error] PRGMAIN.CFC (78): Type of operand is forbidden for used instruction - Upgraded Mosaic from version 2019.1 to 2020.1 SP3 and now got error while compile program with one relational function block (see example on picture)
  • Error E-B1-88-1006 - I'm getting this error, it happened on a few PLCs, all of them are CP-2005. What could cause this error? The TCL2 line is closed with the included resistor and connected in the proper bus structure. IT-1604 module is on the line. Thank you i...
  • how to update firmware of Foxtrot - When I open the firmware updater, the image below is shown. How can I get the latest version and how do I update it? The firmware panel in the image below is empty, and nothing is displayed there.
  • IOConfig and RFox1 - ...eate the configuration manually. When converting the configuration, the RF-1131 module appears in the IO Configurator. It needs to be removed from the configuration and instead of it new files need to be created in the destination project folder and...
  • Examples - ...receive a very simple examples like to use input and output on the PLC Board and I/O on the C-IR-030M CIB. Thank you Regards  ...
  • Taian TW-10 PLC - .... Is it possible that you wanted to reach out to other Teco company based in Taiwan? - https://www.teco.com.tw/en Regards, Michal...
  • Google Home inetgration - ...Maybe because I do not have hardware key... I noticed, that if I turn on CIB or IO module the compile is successful. Regards, Zsolt  ...
  • Analog input - ...es like https://catalog.tecomat.cz/en/product/c-ir-0303m#params that supports 0 - 2 V input range, but not 0 - 10 V. It depends on the solution of inputs circuits and it can't be changed by software configuration....
  • Communicating with MySQL - ...using fb_httpRequest from InternetLib (POST method) but on the server side it has to be used a script that will insert records to MySQL database. An example of such communication is shown in the manual for InternetLib https://www.tecomat.com/modules...
  • HW configurator in Mosaic 2021 - ...rd to use... What is the problem with I/O configurator in my case?  Can you help me please? Thanks in advance! Regards! Zsolt    ...
  • Recurring FC_FILEWRITE error - ...file. You can compare the average value with the value that is set in the project manager in the SW / CPM node. When it exceeds the First warning value and approaches the Crash time, then the risk of write failures is higher. It is enough for a coupl...
  • Modbus TCP on Foxtrot CP-2xxx units - ...master the channel has to be set as TCP client, for Modbus TCP slave it has to be set as a TCP server because the client sends requests and commands and the server fulfils them....
  • Single user web interface for several Foxtrots - ...ties and a convenient toolset for web development. This represents a significant competitive advantage for Foxtrot. These words are like magic to customers: "You don't have to pay for SCADA or additional devices, not even a Raspberry or ESP32." There...
  • CP1005. cannot connect to it via Ethernet cable - ...aged, due to wear and tear or aging. But no one can tell you the exact cause without having a technician look at the PLC boards....
  • cyclically rebooted - This is a hardware error. The PLC needs to replace the capacitors in the ethernet power supply. You can send it to the company address: https://www.tecomat.com/contacts/
  • Color picker wheel for RGB LED dimmer - ...examples. All function blocks are opened, not as a library function blocks, so that you can modify them according to your needs....
  • Apple Homekit blind positioning - ...ot be changed now in order to maintain compatibility of already finished programs of our customers.  The issue of blinds management is quite complex. If you are solving the problem of positioning only, without controlling the blade tilt, you c...
  • Foxtrot integration with various systems - ...wer! How the communication can be realized via Modbus TCP between the Control4 and Foxtrot? What kind of driver Control4 needs?...
  • Webpages left menu. - Hello! Thank you for your example. After studying it and thinking about a solution to my problem, I have a proposal. Could you implement in some future version of WebMaker the ability to add a user-defined HTML class attribute for each page ele...