C-IT-0200R-LOGUS, Pearl, TPETXN 133 20.LTPE
C-IT-0200R-LOGUS pearl; CIB, Indoor temperature sensor, 2x temperature (1x internal, 1x external)
DI | |
---|---|
DO | |
AI | 1x AI (NTC12k, 0-100kΩ) |
AO | |
COM | 1x CIB slave |
SENSOR | 1x Temperature |
Picture | Variant | Variant description |
---|---|---|
C-IT-0200R-LOGUS, white, TBR | Color: White | |
C-IT-0200R-LOGUS, ivory, TMF | Color: Ivory | |
C-IT-0200R-LOGUS, ice, TGE | Color: Ice | |
C-IT-0200R-LOGUS, Pearl, TPE | Color: Pearl | |
C-IT-0200R-LOGUS, aluminum, TAL | Color: Aluminum | |
C-IT-0200R-LOGUS, gray, TIS | Color: Grey | |
C-IT-0200R-LOGUS black | Color: Black | |
C-IT-0200R-LOGUS gold | Color: Gold |
C-IT-0200R-LOGUS; CIB, Indoor temperature sensor, 2x temperature (1x internal, 1x external), white
Order num. | TXN 133 20.LTPE |
---|---|
Teco code | TXN 133 20.LTPE |
Categories | CFox - LOGUS, Covers and devices |
Tags | - |
COM - System buses | |
---|---|
CIB - Common Installation Bus (R): Installation I/O bus | 1x CIB slave |
AI - Analog Input Ranges (Group C) | |
Parameters valid for inputs on the terminals | +IN, -IN |
Passive sensor | NTC Thermistor 12k / 25 °C (-40 to + 125 °C) |
Resistance measurement error - maximum error at 25 ° C | ± 0.5% of full scale |
Parameter des Temperatursensors | |
Temperature - Measurement range | 0°C ÷ 50°C |
Temperature - Resolution | 0,1 °C |
Temperature - Measurement accuracy | typ. ±0,5 °C |
Power supply | |
Supply voltage, tolerances | 24/27 V DC from CIB bus |
Typical power input | 0,3 W |
Maximum power input | < 0,5 W |
Galvanic separation of power supply from internal circuits | No |
Internal protection | Yes, PTC reversible fuse |
Size and weight | |
Weight approx. | 75 g |
Product dimensions (width x height x depth) | 56 x 26 x 16 mm |
Operating conditions, product standards | |
Product standard | ČSN EN 60730-1 ed. 2:2001 (mod IEC 60730-1:1999) |
Protection class of electrical object | III, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016) |
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) | IP10B |
Operating areas | Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005) |
Degree of pollution | 1, according to ČSN EN 60664-1 ed.2:2008 ( idt IEC 60664-1:2007) |
Overvoltage category installation | II, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007) |
Type of device | In the installation box on the wall |
Working position | Any |
Type of operation (operating frequency) | Continuous |
Ambient operating temperatures | 0 °C to + 55 °C |
Operating relative humidity | from 10 % up to 95 % without condensation |
Operating atmospheric pressure | min. 70 kPa (<3,000 m above sea level) |
Storage temperatures | –25 °C to +70 °C |
Electromagnetic compatibility, Mechanical endurance | |
Electromagnetic compatibility / Emission | B, according to EN 55022: 1999 (mod CISPR22: 1997) |
Electromagnetic compatibility / Immunity | min. according to ČSN EN 60730-1 ed.2: 2001 |
Sinusoidal vibration endurance | 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.) |
Packaginng, transportation, storage | |
Description | The module is packed in a paper box. This documentation is also part of the package. The outer packaging is carried out according to the scope of the order and the method of transport in a transport package provided with labels and other data necessary for transport. The product must not be exposed to direct weather conditions during transport and storage. Malting of the product is only allowed in clean rooms without conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C |
Installation | |
Assembly description | Indoor wall mounting |
Connection | |
Connection description |
The module is implemented as a standard unit on a two-wire CIB bus, which ensures communication and power supply of the entire sensor. The bus wires are connected to the wires that are routed on the tube module (see Fig. 2). The CIB bus can have any topology and branching up to a distance of 500 m and up to 32 units on one CIB branch. The CIB bus master is the basic PLC unit TECOMAT FOXTROT or an external CIB bus master, eg the CF-1141 module. Further information can be found in the manual Peripheral modules on the CIB TXV 004 13. Assembly C-IT-0200R-Design: 1. Tube module 2. Temperature sensor in selected interior design |
Connection of power and system communication | Loose wires in the connector / 0.15-0.5 mm2 |
Module connection |
Assembly and installation instructions C-IT-0200R-Design: 1. Connect the module to the CIB bus. 2. Connect an external sensor (if used) to the appropriate wires of the tube module. 3. Slide the temperature sensor connector onto the tips of the tubing module. 4. Insert the tube module into the installation box. Be careful not to disconnect the temperature sensor connector from the tube module. 5. Attach the temperature sensor design to the installation box |
Module operation | |
Module configuration | The module is operated, set up and diagnosed from the Mosaic development environment. |
Commissioning |
The module is ready for operation after connecting the CIB supply voltage. HW address of the relevant module is indicated on the type plate. |
Maintenance | |
Description | The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected. |
Notice | Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!! |
Warranty | |
Generally | Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s. |
Notice | You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change. |
HW documentation
C-IT-0200R-Design - Basic documentation
71.33 kB
User manuals
Peripheral modules on the CIB Common Installation Bus(R) (en), TXV00413_02
13.94 MB, (EN, RU, DE, UA)
Files for designers
Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.
20.49 MB
Foxtrot 2 - element library for SchemataCAD, v. 2024/01
6.79 MB
EC - Declaration of Conformity
Foxtrot - EC Declaration of conformity
295.20 kB, (EN, RU, DE, UA)
No data available.
No data available.