ID-36TXN 054 50.01

ID-36 Operator Panel, Resistive TFT Panel 10 ", Panel Type

DI
DO
AI
AO
COM 1x ETH
1x RS-485
SENSOR
Picture Variant Variant description
ID-36
ID-36 The operator panel is intended for cooperation with TECOMAT TC700, TC800 and Foxtrot systems. User screens are created in the Mosaic programming environment by the WebMaker tool and are identical to the pages that are available in Tecomat via the web server.
The panel has a backlit resistive touch LCD TFT 10" display with a resolution of 800x600 points. It is powered by an external 24 V DC source. Communication between the control system and the ID-3x panel takes place via an Ethernet 100Base-TX interface or via a serial line with an RS-485 protocol interface EPSNET or TCL2 protocol.
The ID-36 panel is designed for built-in installation.
Order num. TXN 054 50.01
Teco code TXN 054 50.01
Categories HMI - Graphic touch panels
Tags Sales and production discontinued
COM - Communication - IP/Ethernet
Ethernet 10/100 Mb (ETHx) 1
Display parameters
Characteristics Color TFT LCD
Diagonal 10,4"
Resolution 800 x 600 pixels
Number of colors 256k
Backlight LED
Backlight lifetime type. 20,000 hours
Touch panel Resistive
Power supply
Nominal supply voltage (V) 24 V DC
Typical power input 7 W
Galvanic separation of power supply from internal circuits No
Internal protection No
Size and weight
Weight approx. 450 g
Product dimensions (width x height x depth) 275 x 216 mm
Operating conditions, product standards
Product standard ČSN EN 61131-2: 2005 (idt IEC61131-2: 2003) - Programmable control units
Protection class of electrical object III, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) IP54 - front panel, IP20 - entire product
Operating areas Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution 2, according to ČSN EN 60664-1 ed.2: 2008 (idt IEC 60664-1: 2007)
Overvoltage category installation II according to ČSN 33 0420-1
Type of device To the panel
Working position Vertical
Type of operation (operating frequency) Continuous
Ambient operating temperatures -20 °C to + 55 °C
Operating relative humidity from 10 % up to 95 % without condensation
Operating atmospheric pressure min. 70 kPa (<3,000 m above sea level)
Storage temperatures –25 °C to +70 °C
Storage environment Dry, clean areas without conductive dust, aggressive gases or acid vapors for a period not exceeding the warranty period.
Transport temperatures -25°C to -70°C
Transport environment Covered means of transport, transport packaging must not be exposed to the effects of rain and snow
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / Emission A, according to EN 55022: 1999 (mod CISPR22: 1997)
Emmisions - note In premises where the use of radio and television receivers can be expected to be used a distance of 10 m from these devices may cause radio interference. In such a case, the user may be required to take appropriate action.
Electromagnetic compatibility / Immunity min. as required by EN 61131-2: 2007
Sinusoidal vibration endurance 10 Hz to 57 Hz amplitude 0.075 mm, 57 Hz to 150 Hz acceleration 1 G, according to Fc according to ČSN EN 60068-2-6 ed.2:2008 (idt IEC 60068-2-6:2007), 10 cycles in each axis .
Packaginng, transportation, storage
Description The module is packed in a paper box. This documentation is also part of the package. The outer packaging is carried out according to the scope of the order and the method of transport in a transport package provided with labels and other data necessary for transport. The product must not be exposed to direct weather conditions during transport and storage. Malting of the product is only allowed in clean rooms without conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C
Installation
Assembly description The ID-36 panel is intended for built-in installation, the front panel is made of aluminum. It's from behind
panel protected only by a cover plate with IP20 protection. Ten metal ones are used for attachment
clip with the fixing screws that are part of it. The mounting hole should have dimensions
264x205 mm.
Operator panels must not be exposed to direct sunlight.
Connection
Connection description The supply voltage of the 24 V DC source is connected to the removable terminal block on the +24 V terminals and
GND, the GND terminal is not galvanically separated from the metal parts of the panel. The clamp is constructed
for screw connection of conductors with a cross-section from 0.5 to 1.5 mm2. It is output on the same terminal block
even RS-485 interface (terminals TxRx+ and TxRx-), EPSNET or TCL2 mode is set by software
in the panel configuration dialog. In the Mosaic environment, the appropriate channel mode must be set
RS-485 (PC for EPSNET protocol) or add a panel in the I/O configurator on the TCL2 bus.
The terminals marked CIB+ and CIB- are prepared for the CIB interface, in the current HW version of the panel
are not used.
Alternatively, the panel can be powered via the Ethernet interface cable, when the supply voltage is 24 V
connects to unused pairs 4/5 and 7/8, the polarity does not matter in this case. Appropriate passive
power injection modules can commonly be purchased at computer hardware stores (often
marked as a PoE module, even though it is not a Power over Ethernet standard).
The ETHERNET interface is connected to a standard 8-pin RJ 45 socket
performed with commonly available cables
Connection via connectors Removable terminal block with screw terminal, wire max. 1.5 mm2
Ethernet RJ-45
Module operation
Module configuration After switching on, the default page will appear on the display. If communication is established with the PLC a
The PLC is in RUN mode, the panel will automatically start uploading user definitions from the PLC
screens and goes into RUN mode. When the PLC is in HALT or unavailable, it remains
the default page with the inscription "HALT" or "Connecting to PLC..." is displayed on the panel. Because
the panel communicates with the PLC protocol EPSNET, it is not listed in the HW configuration of the PLC and its
disconnection does not affect the state of the PLC.
The "Setup" button is located in the lower right corner of the default page. Pressing this button se
brings up a dialog for setting parameters, such as the type of connection to the PLC, IP address of the PLC, IP
panel address, time to turn off the display, default skin theme and more. It's here too
the size of the project files stored in the panel is displayed. If due to frequent
alternating projects, the space has been exhausted (approx. 28MB of data can be stored in the ID-3x) or it would be reduced
file search speed, it is possible to delete these files with the "Clear" button (files
project, which the panel needs for its operation, it will automatically download from the PLC again). Saving
parameters is done with the "Save" button.
If parameters need to be changed in RUN mode, the configuration dialog can be called up by clicking
first to the upper left and then to the lower right corner of the display.
It is also possible to connect to the panel using a web browser on port 8080. If the panel has
set IP address, e.g. 192.168.134.178, just enter the address in the web browser in
of the form http://192.168.134.178:8080 and the web browser will display the panel's configuration pages. You can
there you can set similar parameters as after pressing the "Setup" button directly on the panel, but there is more
here is a page that serves to upgrade the firmware of the panel or display debugs
information
Maintenance
Description The module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected.
Instructions Do not use chemicals such as acetone, toluene, ethanol, isopropyl alcohol to clean the device
etc. Remove dust inside the device with a stream of air or suction. Bezel and front panel
clean with a soft cloth soaked in diluted detergent. For cleaning dusty
or a dirty display touch panel, use a dry, soft cloth, such as a cloth
for cleaning glasses. Remove dirt carefully to avoid scratching the surface layer.
Notice Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!!
Warranty
Generally Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
Notice You must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.

HW documentation

PDF

ID-36 - Basic documentation

167.08 kB
PDF

ID-36 - basic documentation en

1.72 MB, (EN)

Firmware

TXT

Firmware ID-36 - change history

18.46 kB

Files for designers

ZIP

Foxtrot 2 - library of elements in DXF and DWG formats, v. 2024/01.

20.49 MB
KNI

Foxtrot 2 - element library for SchemataCAD, v. 2024/01

6.79 MB
  • Graphic panels with a 10" display, the ID-36 - The operators panel ID-36 is designed for cooperation with TECOMAT TC700 systems and Foxtrot. User screens are created in the Mosaic programming environment with the Webmaker tool, and are therefore identical with the sites accessible via the web...
  • Graphic panels with 4.3“ display, ID-31, ID-32 - ...tening the screws. Fig.  1. Wiring the connectors and connecting the power supply to panels ID-32, ID-31 and ID-36.   Fig. 2. Mechanical dimensions and placement of the ID-32 module connectors Notes:...
  • The operator panels - Several types of operator panels are available for Foxtrot systems (partly also for TC700): ID-31/ID-32 ID-36 ID-14 ID-16

No data available.